Bosch Appliances D6600, D6100 manual Telim Message Type n Byte Description

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 48
Image 48
3.2.26 Telim (Message Type n)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

3.2.26 Telim (Message Type n)

Telim Example

SIA Mode Description

<LF><CRC><n><sequence#><receiver#><line#>[#aaaaaaEETTZZZZZZZZZZZZZZZZZZ]

<CR>

Table 81: Telim (Message Type n) Byte Description

 

 

 

 

Title

Description

 

 

 

 

 

LF

 

Standard line feed character.

CRC

Cyclical redundancy check number.

 

 

Message Type

n

sequence#

The message sequence number. The valid sequence number range is 0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.

line#

The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to

(Line/Group #)

99. The receiver uses Line 0 (zero) for internal messages.

account #

The communicator's account number has up to six digits.

EETTZZZZZZZZZZZZZZZZ

The event type and input line number.

ZZ

 

3.2.27 Varitech FSK 4-1 (Message Type <TAB>)

Varitech FSK 4-1 Example

SIA Mode Description

<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaadata]<CR>

Table 82: Varitech FSK 4-1 (Message Type <TAB>) Byte Description

 

 

 

 

 

 

 

 

Title

 

Description

 

 

LF

 

 

Standard line feed character.

 

 

 

CRC

 

Cyclical redundancy check number.

 

 

Message Type

 

<TAB>

 

 

 

sequence#

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

 

 

 

 

 

receiver#

 

The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.

 

 

 

line#

 

The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99

 

 

(Line/Group #)

 

The receiver uses Line 0 (zero) for internal messages.

 

 

 

 

 

 

 

account#

 

The communicator's account number has four digits.

 

 

 

data

 

The event type and 1-digit zone number.

 

48

Bosch Security Systems, Inc. 1/07 4998122703-01