Bosch Appliances D6600, D6100 manual 3.2.8CFSK Message Type, CFSK Message Type I Byte Description

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 34
Image 34
3.2.8CFSK (Message Type I)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

3.2.8CFSK (Message Type I)

CFSK Example

SIA Mode Description

<LF><CRC><I><sequence#><Receiver#><line#>[#aaaaaaTTEE]<CR>

Table 49: CFSK (Message Type I) Byte Description

 

 

 

 

 

 

Title

 

Description

 

LF

 

Standard line feed character.

 

CRC

 

Cyclical redundancy check number.

 

Message Type

 

I (Capital I).

 

sequence#

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

 

 

 

 

receiver#

 

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.

 

line#

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

 

(Line/Group #)

 

to 99. The receiver uses Line 0 (zero) for internal messages.

 

 

 

 

 

account #

 

The communicator's account number, up to six digits.

 

TT

 

Event code.

 

EE

 

 

Zone/User ID.

3.2.9Common Formats (Message Type <TAB>)

Defined Messages

SIA Example

SIA Mode Description

<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaaaaaaaaaaaaaadata]<CR>

Table 50: Common Formats (Message Type <TAB>) Byte Description

 

 

 

 

 

Title

 

Description

 

 

 

 

 

 

LF

 

 

Standard line feed character.

CRC

 

Cyclical Redundancy Check number.

 

 

 

Message Type

 

09 hex <TAB>

sequence#

 

The message sequence number. The valid sequence number range is 0001 to 9999.

receiver#

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.

line#

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

(Line/Group #)

 

to 99. The receiver uses Line 0 (zero) for internal messages.

account#

 

The communicator's account number up to sixteen digits.

Data

 

This field contains message data codes such as event type, area number, point number,

 

 

 

 

identification number, and so on.

 

 

 

 

 

The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem

IIor Modem IId messages in either D6500 Mode or SIA Mode, depending on the program option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the programmable option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C:

Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.

Figure 12: Message sent to printer

MM/DDsHH:MMsLxxSIA ACCT aaaa

+++TEXT 1

+++TEXT 2

34

Bosch Security Systems, Inc. 1/07 4998122703-01

Page 34
Image 34
Bosch Appliances D6600 3.2.8CFSK Message Type, CFSK Message Type I Byte Description, 3.2.9Common Formats Message Type TAB