Table 92: Modem IIIa2 Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Event

Device/Mode

Display

 

 

Explanation

Refer to Section

 

 

 

 

 

 

 

 

 

C.1 Zonex and

 

 

 

 

 

 

 

 

 

Comex

 

 

 

 

 

 

 

 

 

Translation on

 

 

 

 

 

 

 

 

 

page 137.

 

 

 

 

 

 

 

 

 

 

 

 

388.

Forced Point

Printer:

dd/dd tt:tt Lxx ACC aaaa

FORCED POINT

The POINT in the

1,

 

 

 

 

 

 

+++ ACC aaaa

AREA=a POINT=ppp

AREA in the second

6,

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTspppt

 

line of the report was

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaXWppp]

 

faulted and bypassed

D9112

 

 

 

 

 

when the system was

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

armed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

389.

Forced Point

Printer:

dd/dd tt:tt Lxx ACC aaaa

FORCED POINT

The POINT in the

1,

 

 

 

 

(ID not

 

+++ ACC aaaa

AREA=a POINT=ppp

AREA in the second

6,

 

 

 

 

reported)

D6500 Mode:

h1rrlssssssaaaasTspppt

 

line of the report was

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaXWppp]

 

faulted and bypassed

D7112

 

 

 

 

 

when the system was

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

armed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

390.

Forced Point

Printer:

dd/dd tt:tt Lxx ACC aaa

TROUBLE ZN z

 

9.

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTssszt

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNBTz]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

391.

Forced Point

Printer:

dd/dd tt:tt Lxx ACC aaaa

FORCED POINT

 

 

 

 

 

 

(point > 254)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTppppt

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNriaaXWpppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

392.

Invalid Local

Printer:

dd/dd tt:tt Lxx ACC aaaa PROG ACCESS BAD

An unsuccessful

D9112

 

 

 

Access

 

+++ ACC aaaa

SDI=ddd

 

attempt was made to

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasTsF01t

 

locally access the

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNpidddLU]

 

account through the

 

 

 

 

 

 

 

 

 

 

supervised keypad or

 

 

 

 

 

 

 

 

 

 

other serial device

 

 

 

 

 

 

 

 

 

 

specified in the second

 

 

 

 

 

 

 

 

 

 

line of the report.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

393.

Invalid

Printer:

dd/dd tt:tt Lxx ACC aaa

TROUBLE ZN F

Abnormal RAM session

2.

 

 

 

termination or

 

 

 

 

Remote

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

 

 

 

 

 

 

beginning of the

 

 

 

 

 

Access

SIA Mode:

<header>[#aaaaNBTF]

 

 

 

 

 

 

 

Command 58 Fire Test.

 

 

 

 

 

 

 

 

 

 

 

394.

Invalid

Printer:

dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL

An unsuccessful

D9112

 

 

 

Remote

 

+++ ACC aaaa

PHONE#=5

 

attempt was made by a

 

 

 

 

 

Access

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

RAM to contact the

 

 

 

 

 

(phone not

SIA Mode:

<header>[#aaaaNph5RU]

 

account on the

 

 

 

 

 

reported)

 

 

 

 

PHONE# specified in

 

 

 

 

 

 

 

 

 

 

the second line of the

 

 

 

 

 

 

 

 

 

 

report.

 

 

 

 

 

 

 

 

 

 

 

 

 

395.

Invalid

Printer:

dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL

 

 

 

 

 

 

Remote

 

+++ACC aaaa

 

PH#=hh

 

 

 

 

 

 

Access

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

 

 

 

 

 

 

(from Call

SIA Mode:

<header>[#aaaaNphhhRU]

 

 

 

 

 

 

 

Back)

 

 

 

 

 

 

 

 

 

396.

Invalid

Printer:

dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL

An unsuccessful attempt

D9112

 

 

 

Remote

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

was made by a RAM to

 

 

 

 

 

Access

SIA Mode:

<header>[#aaaaNpRU]

 

contact the account on

 

 

 

 

 

 

the PHONE# specified

 

 

 

 

 

(no call back)

 

 

 

 

 

 

 

 

 

 

 

 

in the second line of the

 

 

 

 

 

 

 

 

 

 

report.

 

 

 

 

397.

Invalid

Printer:

dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL

An unsuccessful attempt

D7112

 

 

 

Remote

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

was made by a RAM to

 

 

 

 

 

Access

SIA Mode:

<header>[#aaaaNphhRU]

 

contact the account on

 

 

 

 

 

 

the PHONE# specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the second line of the

 

 

 

 

 

 

 

 

 

 

report.

 

 

 

 

398.

Invalid

Printer:

dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL

An unsuccessful attempt

 

 

 

 

 

Remote

D6500 Mode:

h1rrlssssssaaaasTsssFt

 

was made by a RAM to

 

 

 

 

 

 

contact the account on

 

 

 

 

 

Access

SIA Mode:

<header>[#aaaaNRU]

 

 

 

 

 

 

 

the PHONE# specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the second line of the

 

 

 

 

 

 

 

 

 

 

report.

 

 

 

 

399.

Invalid Report

Printer:

dd/dd tt:tt Lxx ACC aaaa

INVALID REPORT

 

 

 

 

 

 

 

D6500 Mode:

h1rrlsssssssssssXss26t

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNYN]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 1/07 4998122703-01

 

 

95

Page 95
Image 95
Bosch Appliances D6100, D6600 Modem IIIa2 Messages continued, Bosch Security Systems, Inc. | 1/07, C.1 Zonex and, Comex