Bosch Appliances D6100, D6600 3.2.6ADT SIA Message Type <TAB>, 3.2.7Caller ID Message Type <TAB>

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 33
Image 33
3.2.6ADT SIA (Message Type <TAB>)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

3.2.6ADT SIA (Message Type <TAB>)

ADT SIA Example

SIA Mode Description

<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa<E><damm-dd- yytihh:mm:ss>data]<CR>

Table 47: ADT SIA (Message Type <TAB>) Byte Description

 

 

 

 

 

 

Title

 

Description

 

 

 

 

 

 

LF

 

 

Standard line feed character.

 

CRC

 

Cyclical redundancy check number.

 

 

 

 

 

Message Type

 

09 hex <TAB>.

 

sequence#

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

receiver#

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.

 

line#

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

 

(Line/Group #)

 

to 99. The receiver uses Line 0 (zero) for internal messages.

 

account#

 

The communicator's account number up to sixteen digits.

 

E

 

Event Code (refer to Appendix G ADT SIA Report Codes on page 149).

 

 

 

 

 

damm-dd-yytihh:mm:ss

 

Date and time.

 

Data

 

This field contains message data codes such as event type, area number, point number,

 

 

 

 

identification number.

3.2.7Caller ID (Message Type <TAB>)

SIA Example

SIA Mode Description

<LF><CRC><TAB><sequence#><receiver#><line#>[&TTTTTTTTTTTTTTTT]<CR>

Table 48: Caller ID (Message Type <TAB>) Byte Description

 

 

Title

Description

LF

Standard line feed character.

CRC

Cyclical Redundancy Check number.

Message Type

<TAB>

sequence#

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.

line#

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

(Line/Group #)

to 99. The receiver uses Line 0 (zero) for internal messages.

 

 

&

Origin ID Block.

T

Up to 16-digit Caller ID.

Bosch Security Systems, Inc. 1/07 4998122703-01