Bosch Appliances D6100, D6600 FBI Super Fast Message Type F, Computer Communication Protocols

Models: D6100 D6600

1 168
Download 168 pages 55.61 Kb
Page 37
Image 37
3.2.12 FBI Super Fast (Message Type F)

Conettix D6600/D6100 Computer Interface Manual

3.0

Computer Communication Protocols

 

 

 

3.2.12 FBI Super Fast (Message Type F)

FBI Super Fast Example

SIA Mode Description

<LF><CRC><F><sequence#><receiver#><line#>[#aaaaTZZE]<CR>

Table 57: FBI Super Fast (Message Type F) Byte Description

 

 

 

 

 

Title

 

Description

LF

 

Standard line feed character.

CRC

 

Cyclical redundancy check number.

Message Type

 

F

sequence#

 

The message sequence number. The valid sequence number range is 0001 to 9999.

 

 

 

 

 

 

receiver#

 

 

The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.

line#

 

The line number of the line in the receiver gateway that sent the message. Valid digits are 00

(Line/Group #)

 

to 99. The receiver uses Line 0 (zero) for internal messages.

 

 

 

account#

 

The communicator's account number has four digits.

T

 

Zone type.

 

ZZ

 

 

Zone number.

E

 

Event type.

 

 

 

 

 

Figure 16: Message sent to printer

mm/ddshh:mmsLxxsFBIsACCTsaaaasTZZE+++s ACCsaaaastttttttttseeeeeeeesiisnnn

For lines that are grouped, Gxx appears instead of Lxx.

Table 59: Event Code Table

 

 

Code

Zone/Event Type

1

Fire

2

Panic

3

Burglary

4

Medical

5

Auxiliary

6

Bypass

7

Inactive

8

Eight

9

Nine

0

Zero

B

Opening

C

Closing

D

Abort

E

Restore

F

Trouble

Table 58: FBI Super Fast (Message Type F)

 

 

Printer Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Characters

 

 

Description

 

 

 

 

 

 

 

 

FBI

 

 

FBI Super Fast format.

 

 

Lxx:

 

 

Line number.

 

 

Gxx

 

 

Grouped line numbers.

 

 

 

 

 

 

 

Table 60: Printer Output Codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Characters

 

 

Description

 

 

ii

 

 

ZN=Zone number - ID=User ID

 

 

nnn

 

 

Zone/User number.

 

tttttttttUp to nine-character zone type, right justified FIRE, PANIC, BURGLARY, MEDICAL, AUXILIARY.

eeeeeeeeUp to eight-character event type, left justified ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL.