Table 92: Modem IIIa2 Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Event

Device/Mode

Display

 

 

Explanation

Refer to Section

 

 

 

 

 

 

 

 

 

C.1 Zonex and

 

 

 

 

 

 

 

 

 

Comex

 

 

 

 

 

 

 

 

 

Translation on

 

 

 

 

 

 

 

 

 

page 137.

 

 

 

 

 

 

 

 

 

 

 

 

705.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

 

CROSS POINT

 

 

 

 

 

(points < 255)

 

+++ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFspppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaFAppp]

 

 

 

 

 

706.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

 

SMOKE DETECTOR

 

 

 

 

 

(points < 255)

 

+++ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFspppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaFAppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

707.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

HIGH TEMPERATURE SENSOR

 

 

 

 

 

(points < 255)

 

+++ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFspppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaFAppp]

 

 

 

 

 

708.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

WATER FLOW SENSOR

 

 

 

 

 

(points < 255)

 

+++ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFspppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaFAppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

709.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

(points > 254)

D6500 Mode:

h1rrlssssssaaaaSFppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFApppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

710.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

 

CROSS POINT

 

 

 

 

 

(points > 254)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFApppp]

 

 

 

 

711.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

 

SMOKE DETECTOR

 

 

 

 

 

(points > 254)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFApppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

712.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

HIGH TEMPERATURE SENSOR

 

 

 

 

 

(points > 254)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFApppp]

 

 

 

 

713.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE ALARM

 

 

 

 

 

Alarm

 

+++ACC aaaa

WATER FLOW SENSOR

 

 

 

 

 

(points > 254)

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSFppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFApppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

714.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE MISSING

 

 

 

 

 

Missing

 

+++ ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSZspppt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaFYppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

715.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa

S:FIRE MISSING

 

 

 

 

 

Missing

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

(points > 254)

D6500 Mode:

h1rrlssssssaaaaSZppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFYpppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

716.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa S:FIRE SUPRVISN

 

 

 

 

 

Supervision

 

+++ ACC aaaa

AREA=a POINT=ppp

 

 

 

 

 

 

D6500 Mode:

h1rrlssssssaaaaSEspppt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaFSppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

717.

Status: Fire

Printer:

dd/dd tt:tt

Lxx ACC aaaa S:FIRE SUPRVISN

 

 

 

 

 

Supervision

 

+++ACC aaaa

AREA=aa POINT=pppp

 

 

 

 

 

(points < 255)

D6500 Mode:

h1rrlssssssaaaaSEppppt

 

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaOriaaFSpppp]

 

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 1/07 4998122703-01

 

 

121

Page 121
Image 121
Bosch Appliances D6100, D6600 Modem IIIa2 Messages continued, Bosch Security Systems, Inc. | 1/07, C.1 Zonex and, Comex