Table 92: Modem IIIa2 Messages (continued)

 

 

 

 

 

 

 

 

 

Event

Device/Mode

Display

 

Explanation

Refer to Section

 

 

 

 

 

 

C.1 Zonex and

 

 

 

 

 

 

Comex

 

 

 

 

 

 

Translation on

 

 

 

 

 

 

page 137.

 

 

 

 

 

 

 

 

359.

Force Close

Printer:

dd/dd tt:tt Lxx ACC aaaa

F CLOSE EARLY

A user with the ID in

1,

 

 

Early

 

+++ ACC aaaa

AREA=a

the second line of the

D7112

 

by Account

D6500 Mode:

h1rrlssssssaaaasCsssst

 

report armed the

 

 

 

 

 

(ID not

SIA Mode:

<header>[#aaaaNriaCF]

 

AREA in the second

 

 

 

reported)

 

 

 

line of the report after

 

 

 

 

 

 

 

the programmed

 

 

 

 

 

 

 

closing time while

 

 

 

 

 

 

 

points in the AREA

 

 

 

 

 

 

 

were faulted. Faulted

 

 

 

 

 

 

 

points were not armed.

 

 

 

 

 

 

 

 

 

 

360.

Force Close

Printer:

dd/dd tt:tt Lxx ACC aaaa

F CLOSE EARLY

A user with the ID in

1,

 

 

Early

 

+++ ACC aaaa

ID=iii

the second line of the

D7112 by Account

 

by Account

D6500 Mode:

h1rrlssssssaaaasCsiiit

 

report armed the

 

 

 

 

 

 

SIA Mode:

<header>[#aaaaNidiiiCF]

 

AREA in the second

 

 

 

 

 

 

 

line of the report after

 

 

 

 

 

 

 

the programmed

 

 

 

 

 

 

 

closing time while

 

 

 

 

 

 

 

points in the AREA

 

 

 

 

 

 

 

were faulted. Faulted

 

 

 

 

 

 

 

points were not armed.

 

 

 

 

 

 

 

 

 

 

361.

Force Close

Printer:

dd/dd tt:tt Lxx ACC aaa

CLOSING REPORT

The system

2,

 

 

Early

 

dd/dd tt:tt Lxx ACC aaa

WAS FORCE ARMED

armed/disarmed with a

D7112

 

by Account

D6500 Mode:

h1rrlssssssaaaasCsssst

 

passcode or

 

 

 

 

 

(ID not

 

h1rrlssssssaaaasWsssst

 

COMMAND 1

 

 

 

reported)

SIA Mode:

<header>[#aaaaNCL]

 

reporting no User ID

 

 

 

 

 

<header>[#aaaaNCW]

 

(D8112G2 excluded).

 

 

 

 

 

 

AREA armed by user

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with the ID in the

 

 

 

 

 

 

 

second line of the

 

 

 

 

 

 

 

report

 

 

 

 

 

 

 

Account armed with

 

 

 

 

 

 

 

zones or points faulted.

 

 

 

 

 

 

 

The faulted zones or

 

 

 

 

 

 

 

POPITs were not

 

 

 

 

 

 

 

armed. Zones, areas, or

 

 

 

 

 

 

 

points that were not

 

 

 

 

 

 

 

armed are indicated by

 

 

 

 

 

 

 

a TROUBLE or

 

 

 

 

 

 

 

SHUNTED report.

 

 

 

 

 

 

 

 

 

 

362.

Force Close

Printer:

dd/dd tt:tt Lxx ACC aaaa

F CLOSE EARLY

A user with the ID in

1,

 

 

Early

D6500 Mode:

h1rrlssssssaaaasCsssst

 

the second line of the

D7112

 

by Account

SIA Mode:

<header>[#aaaaNCF]

 

report armed the

 

 

 

 

 

(ID not

 

 

 

AREA in the second

 

 

 

reported)

 

 

 

line of the report after

 

 

 

 

 

 

 

the programmed

 

 

 

 

 

 

 

closing time while

 

 

 

 

 

 

 

points in the AREA

 

 

 

 

 

 

 

were faulted. Faulted

 

 

 

 

 

 

 

points were not armed.

 

 

 

 

 

 

 

 

 

 

363.

Forced Close

Printer:

dd/dd tt:tt Lxx ACC aaaa

F CLOSE LATE

A user with the ID in the

1,

 

second line of the report

 

 

Early by Area

 

+++ ACC aaaa

AREA=a ID=iii

 

 

 

 

armed the AREA in the

 

 

 

 

D6500 Mode:

h1rrlssssssaaaasCsiiit

 

 

 

 

 

 

second line of the report

 

 

 

 

SIA Mode:

<header>[#aaaaNria/idiiiCF]

after the programmed

 

 

 

 

 

 

 

closing time while points

 

 

 

 

 

 

 

in the AREA were

 

 

 

 

 

 

 

faulted. Faulted points

 

 

 

 

 

 

 

were not armed.

 

 

Bosch Security Systems, Inc. 1/07 4998122703-01