Bosch Power Tools 2000 Point User Flag, Series Program Entry Guide, Reports, Default, Selection

Models: 2000

1 72
Download 72 pages 25 Kb
Page 13
Image 13
8 Point User Flag

2000 Series Program Entry Guide 3.0

Reports

 

 

When set to Buzz, Report the system flashes the OK light at the keypad, sounds the trouble tone, and sends an AC Fail Report to the receiver.

When set to Buzz, Tag-Along Rpt the system flashes the OK light and sounds the trouble tone at the keypad after 60 seconds. It sends an AC Fail Report to the receiver as a tag along with all reports sent to the receiver until AC restores.

When set to No Buzz, Report the system flashes the OK light at the keypad and sends an AC Fail Report to the receiver.

When set to No Buzz, Tag-Along Rpt the system flashes the OK light. It sends an AC Fail Report to the receiver as a tag along with all reports sent to the receiver until AC restores.

8 Point User Flag

Default:

No

 

 

 

Selection:

Yes, No

 

 

 

0

 

No

 

 

 

1

 

Yes

 

 

 

Set this prompt to Yes to send a flag with each Modem II Report that tells the D6500 to convert point numbers to Bosch Security System’s D8112 style Zonex Format, and User ID numbers to D8112 type COMEX Format.

Bosch Security Systems 7/05 35114F

EN 13

Page 13
Image 13