6.2Exit

2000 Series Program Entry Guide 6.0

Open/Close

 

 

6.2Exit

If you enable the Exit feature, pressing the [CLEAR] key at the keypad when the system is On with No Delay starts exit delay. The system sounds the exit delay tone (if Exit Tone is programmed Yes) and bypasses all points programmed for exit delay (Digit 1 of point code is 6 or 8). The rest of the system remains On with No Delay. The tone and bypass remain until exit delay expires. The system returns to the On with No Delay state. The Exit feature allows one user to exit a system that is On with No Delay, leaving those left inside fully protected.

If the user presses [CLEAR] during the exit delay, the system returns to On with No Delay.

A faulted point (open door) at the end of exit delay creates an Exit Error alarm.

If an alarm occurs within 2 minutes of the end of exit delay, the system sends an Alarm Recent Close Report.

All Exit: Only allows users access to the Exit feature when the system is All On with No Delay (instant).

Part Exit: Only allows users access to the Exit feature when the system is Part On with No Delay (instant).

All & Part Exit: Allows users access to the Exit feature when either All or Part of the system is All On with No Delay (instant) or Part On with No Delay (instant).

Bosch Security Systems 7/05 35114F

EN 25

Page 25
Image 25
Bosch Power Tools 2000 manual 6.2Exit, Series Program Entry Guide, Open/Close