5 No Delay

2000 Series Program Entry Guide 6.0

Open/Close

 

 

EN 24

Program Exit Tone Yes to enable the exit delay tone and excursion tone.

Program Exit Tone No to disable the exit delay tone and excursion tone.

5 No Delay

Default:

Part On

 

 

Selection:

Disabled, Part On, All On, All & Part

 

 

0

Disabled

 

 

1

Part On

 

 

2

All On

 

 

3

All & Part

 

 

The No Delay prompt allows users to turn their system on with No Entry or Exit Delay (instant arming). If this prompt is set to Part On, users can turn their system Part On with No Delay by pressing the [0] key twice.

If this prompt is set to All On, users can turn their system All On with No Delay by pressing the [9] key twice. If this prompt is set to All & Part, users can turn their system All or Part On with No Delay.

If this prompt is set to Disabled, users cannot turn their system on with No Delay. Entry and exit delay are always provided.

Selecting Disabled for the No Delay prompt also disables the Excursion feature. Refer to the Excursion prompt.

6 Excursion

Default:

Disabled

Selection:

Disabled

 

All Step

 

Part Step

 

All & Part Step

 

All Exit

 

Part Exit

 

All & Part Exit

 

 

0

Disabled

 

 

1

All Step

 

 

2

Part Step

 

 

3

All & Part Step

 

 

4

All Exit

 

 

5

Part Exit

 

 

6

All & Part Exit

 

 

Use the Excursion prompt to configure the system for either the Step Outside or Exit User features.

6.1Step Outside

If you enable the Step Outside feature, pressing the [CLEAR] key at the keypad when the system is on with No Delay starts the exit delay tone (if Exit Tone is programmed Yes) and bypasses all points programmed for delay (Digit 1 of point code = 6 or 8). The rest of the system remains on.

The tone and bypass remain until the user presses the [CLEAR] key a second time, returning the system to its fully on state. If a point is faulted when the user presses the [CLEAR] key the second time, the tone and bypass continue. The user must either clear the fault (close the door) or turn the system off with a passcode.

The Step Outside feature allows users to pick up the morning paper or let the dog out without turning the system off.

All Step: Only allows users access to the Step Outside feature when the system is All On with No Delay (instant).

Part Step: Only allows users access to the Step Outside feature when the system is Part On with No Delay (instant).

All & Part Step: Allows users access to the Step Outside feature when either All or Part of the system is On with No Delay (instant).

Bosch Security Systems 7/05 35114F

Page 24
Image 24
Bosch Power Tools 2000 manual 6.1Step Outside, No Delay, Excursion, Series Program Entry Guide, Open/Close