11.6 Recommended Point Codes

2000 Series Program Entry Guide 11.0

Point Codes

 

 

11.6 Recommended Point Codes

EN 48

Table 10 through Table 16 show some recommended point codes. Many other point code options are available. You can create custom point functions using the many point features available. Be sure to thoroughly test any point code to be certain the system functions as you expect.

Table 10: Smoke Detector (trouble on open, alarm output)

 

Reports

Local

Alarm verification (Pt 1 only)

260##

250##

No verification

160##

150##

Cross point

168##

158##

Partner point

16C##

15C##

 

 

 

RF point

160##

150##

Table 11: Door with Entry/Exit Delay (swinger bypass, alarm output, alarm report delay)

 

Reports

Local

Delay on Open

882##

852##

Trouble on Short

 

 

Delay on Short

881##

851##

Trouble on Open

 

 

Delay on Open or Short

880##

850##

No Troubles

 

 

RF point

880##

850##

 

 

 

Table 12: Door or Window with No Entry/Exit Delay (swinger bypass, alarm output, alarm report delay)

 

Reports

Local

Trouble on Short

982##

952##

Trouble on Open

981##

951##

 

 

 

No Troubles

980##

950##

RF point

980##

950##

 

 

 

Table 13: Garage Door with Extended Entry/Exit Delay (swinger bypass, alarm output, alarm report delay)

 

Reports

Local

Trouble on Short

B82##

B52##

Trouble on Open

B81##

B51##

 

 

 

No Troubles

B80##

B50##

RF point

B80##

B50##

 

 

 

Table 14: Motion Detector (swinger bypass, alarm output, alarm report delay)

 

Reports

Local

Trouble on Short

782##

752##

Trouble on Open

781##

751##

No Troubles

780##

750##

Cross point

78A##

75A##

Trouble on Short

 

 

Cross point

789##

759##

Trouble on Open

 

 

Cross point

788##

758##

No Troubles

 

 

Partner point

78E##

75E##

Trouble on Short

 

 

Partner point

78D##

75D##

Trouble on Open

 

 

Partner point

78C##

75C##

No Troubles

 

 

RF point

780##

750##

 

 

 

 

 

 

Table 15: Tamper (swinger bypass, alarm output, alarm report delay)

 

Reports

Local

Trouble on Short

782##

752##

Trouble on Open

781##

751##

No Troubles

780##

750##

RF point

780##

750##

 

 

 

Bosch Security Systems 7/05 35114F