Bosch Power Tools 2000 manual Series Program Entry Guide, Receiver, continued

Models: 2000

1 72
Download 72 pages 25 Kb
Page 16
Image 16
Table 2: continued

2000 Series Program Entry Guide 4.0

Receiver

 

 

EN 16

Table 2: continued

Modem II Report

CLOSING REPORT

CLOSING REPORT ID 001 (-008)

COMM FAIL

PHONE (1-2)

COMM RESTORAL

PHONE (1-2)

DURESS

ID 008

EXIT ERROR 001 (-024)

FIRE ALARM POINT 001 (-099)

FIRE ALARM CROSS POINT 001 (-024)

MISSING ALARM POINT 001 (-024)

MISSING TROUBLE POINT 001 (-024)

OPENING REPORT

OPENING REPORT ID 001 (-008)

OPEN FROM ALARM

OPEN FROM ALARM ID 001 (-008)

PERM INST ARMED

PERM INST ARMED ID 001 (-008)

PERM DLAY ARMED

PERM DLAY ARMED ID 001 (-008)

Description

Closing Report when passcode is not used. Refer to the Passcode Rquired prompt in Section

15.0Passcodes. Using a Keyswitch or a remote programmer also sends this Closing Report with no user ID.

Closing Report with user ID for users 1 to 8.

Communication Failure event. Refer to Phone 1, Phone 2 in Section 2.0 Phone.

Successful communication after a Communication Failure event. Refer to Phone 1, Phone 2 in the Section 2.0 Phone.

Passcode 8 used to turn the system on, turn the system off, or to silence an alarm. Refer to the Code 8 = Duress prompt in Section 15.0 Passcodes.

When a point is faulted at the end of exit delay it generates an Exit Alarm.

Exit Alarm Report from Points 1 to 24.

Fire Alarm Report from Points 1 to 24.

Cross Point Fire Alarm Report from Points 1 to 24.

Missing Non-fire Controlled point, point is on (armed). Alarm response locally.

Missing Non-fire Controlled point, point is off (disarmed), or 24-hour Non-fire point. Trouble response locally.

Turning the system off with a keyswitch or a remote programmer sends this Opening Report with no User ID.

Opening Report with User ID for users 1 to 8.

Turning the system off after an alarm with a Keyswitch point or a remote programmer sends this Opening Report with no User ID.

Opening Report after an alarm with User ID for users 1 to 8.

Remote programmer used to turn the system Part On with No Delays, or user turned the system Part On with No Delays and no passcode required. Refer to the Passcode Rquired prompt in Section 15.0 Passcodes.

User with ID shown (1 to 8) turned the system Part On with No Delays.

Remote programmer used to turn the system Part On (with Delays), or user turned the system Part On with Delays and no passcode required. Refer to the Passcode Rquired prompt in Section 15.0 Passcodes.

User with ID shown (1 to 8) turned the system Part On (with Delays).

Bosch Security Systems 7/05 35114F

Page 16
Image 16