Bosch Power Tools 2000 Non-FireGroup, Pt Trbl Group, Restoral Group, Closing Group, Opening Group

Models: 2000

1 72
Download 72 pages 25 Kb
Page 19
Image 19
3 Non-Fire Group

2000 Series Program Entry Guide 4.0

Receiver

 

 

EN 19

3 Non-Fire Group

Default:

 

0

 

 

Selection:

 

 

0 to 9, B to F

 

 

 

 

 

 

 

 

 

 

 

1 to 8

Non-Fire alarm from Points 1 to 24.

 

 

 

9 or 0

 

Non-Fire alarm from key A, B, or C.

 

 

 

 

Refer to Section 7.0 ABC Keys.

 

 

 

 

There are no Pulse Format versions of

 

 

 

 

the Modem II Alarm recent Close,

 

 

 

 

Alarm Cross Point, or Exit Alarm

 

 

 

 

Reports. All occur as Alarm Reports.

 

 

 

 

The Cross Point feature creates two

 

 

 

 

point alarms. Refer to Section 11.0 Point

 

 

 

 

Codes.

 

 

 

 

 

 

4 Pt Trbl Group

Default: 0

Selection: 0 to 9, B to F

1 to 8 Trouble, Missing, Bypass, or Swinger Bypass Reports from Fire and Non-Fire points combined.

Multiple trouble conditions can create duplicate Trouble Reports. For example, a point can send a trouble for a open sensor loop, then a trouble for missing.

5 Restoral Group

Default: 0

Selection: 0 to 9, B to F

1 to 8 Restoral on points 1 to 24, Fire and Non-Fire combined.

6 Closing Group

Default:

0

Selection:

0 to 9, B to F

 

 

0

Closing Report when a passcode is not

 

required to turn system on (refer to

 

Passcode Rquired prompt in Section

15.0 Passcodes) or a keyswitch is used.

1 to 8 Closing Report with User ID for users 1 to 8.

7 Opening Group

 

 

Default:

 

0

 

 

 

Selection:

 

 

0 to 9, B to F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

Opening Report when keyswitch is

 

 

 

 

used, or Part On No Delay, or Part On

 

 

 

 

with delay.

 

 

 

 

 

 

 

1 to 8

Opening Report with User ID for users

 

 

 

 

1 to 8.

 

 

 

 

 

 

 

 

8 Cancel Group

 

 

 

 

 

 

 

 

Default:

 

0

 

 

 

Selection:

 

 

0 to 9, B to F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

Cancel Report when keyswitch is used.

 

 

 

 

 

 

1 to 8

Cancel Report with User ID for users 1

 

 

 

 

to 8.

 

 

 

 

 

 

 

9 Sys Trbl Group

Default: 0

Selection: 0 to 9, B to F

1Reports an unsuccessful attempt to connect a remote programmer.

2Reports an unsuccessful attempt to connect a remote programmer.

3The system automatically reset. Call Bosch Security Systems if reports persist.

4Not used.

5 Not used.

6 Reports missing battery.

7 Reports low battery.

8No AC power to system. Control panel is running on battery.

9Communication Failure event for Phone 1.

B Communication Failure event for Phone 2.

C RF tamper (points or receiver).

D RF low battery.

E RF receiver 7 trouble.

F RF receiver 8 trouble.

Bosch Security Systems 7/05 35114F

Page 19
Image 19
Bosch Power Tools 2000 Non-FireGroup, Pt Trbl Group, Restoral Group, Closing Group, Opening Group, Cancel Group, Receiver