2000 Series Program Entry Guide 4.0

Receiver

 

 

EN 17

Table 2: continued

Modem II Report

POINT BYPASS POINT 001 (-024)

RAM ACCESS OK

RAM ACCESS FAIL

RESTORAL REPORT POINT 001 (-024)

Description

Point 1 to 24 bypassed. Points can be bypassed from the keypad or from a remote programmer. Bypass Reports are only sent when Opening and Closing Reports are enabled in Section 6.0 Open/Close.

Normal remote programmer session termination.

Remote programmer made connection with control panel, but passcode was incorrect, or call was not terminated with a Good-bye or Reset-Bye.

Restoral Report from Points 1 to 24.

RE-BOOT

RF BATTERY LOW POINT 001 (-024)

Control panel reset with the standby pin (Refer to Installation Manual) or a remote programmer.

Low battery in RF sensor, keypad, or arming device.

RF BATT RESTORE

Restored battery in RF sensor, keypad, or arming device.

POINT 001 (-024)

 

 

 

RF Rcvr Tamper SDI 7 (8)

RF Rcvr Tamper

Restoral

SDI 7 (8)

RF Rcvr Trouble Device 7 (8)

Enclosure tamper from premises RF receiver (D208RF, D216RF).

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

Enclosure tamper restoral from premises RF receiver (D208RF, D216RF).

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

Trouble from premises RF receiver (D208RF, D216RF)

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

RF Rcvr Trbl

Restoral from premises RF receiver (D208RF, D216RF)

Restoral

 

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

Device 7

(8)

 

RF TAMPER TROUBLE

RF TAMPER RESTORAL

SERVICE START

SERVICE STOP

SWINGER BYPASS POINT 001 (-024)

TEST REPORT

TROUBLE REPORT POINT 001 (-024)

Tamper RF point, Controlled point, system off.

Tamper restoral, RF point.

Installer mode entered (Stand-by locked down, installer passcode entered).

Installer mode exited.

Points 1 to 24 bypassed automatically by the system after four alarms or troubles in one armed or disarmed period. You can program the Swinger Bypass feature to activate after less than four alarms or troubles. Refer to Swinger Count prompt in Section 1.0 System Configuration.

Use the point code to program this feature by point. Refer to Section 11.0 Point Codes.

Automatic Test Timer Report.

Trouble on Points 1 to 24, Fire and Non-fire combined.

USR CODE

TAMPER

This report transmitted after six attempts to enter an invalid passcode.

WATCHDOG

RESET

System automatically reset. Call Bosch Security Systems if reports persist.

 

 

 

 

 

 