11.2Digit 2, Alarm Responses

2000 Series Program Entry Guide 11.0

Point Codes

 

 

EN 43

11.2Digit 2, Alarm Responses

Table 6: Digit 2 Selections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

 

No Alarm Response: Set Digit 2 to 0 (zero) only if you want no alarm response for

X

 

 

 

 

 

 

 

 

 

 

 

this point.

 

 

 

 

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

 

 

Set Digit 2 to 0 if you are using this point number for an RF Keypad or arming device.

 

 

 

 

 

 

 

 

 

 

 

 

Reports: Points send Alarm, Cancel, Trouble, Bypass, Swinger Bypass, and Restoral

 

X

X

X

X

 

X

X

X

 

X

 

Reports as programmed. Bypass Reports are only sent with Closing Reports.

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Report Delay: If a user enters their passcode to silence an alarm before the

 

 

X

X

 

 

 

X

X

 

 

 

programmed Alarm Report Delay time expires, the alarm is canceled. No Alarm,

 

 

 

 

 

 

 

 

 

 

 

 

Cancel, or Restoral Report is sent. Program Delay Alrm Rpt in Section 3.0 Reports

 

 

 

 

 

 

 

 

 

 

 

 

to determine the duration of the delay.

 

 

 

 

 

 

 

 

 

 

 

 

Voice Active Function: When the Delay Alrm Rpt prompt is set to 255, Alarm

 

 

 

 

 

 

 

 

 

 

 

 

Report Delay points (Digit 2 = 2, 3, 7, or 8) begin the 2-way Voice Verification

 

 

 

 

 

 

 

 

 

 

 

 

process. Refer to Delay Alrm Rpt in Section 3.0 Reports.

 

 

 

 

 

 

 

 

 

 

 

 

Duress Reports and A, B, C Key Reports are not affected by the Alarm Report

 

 

 

 

 

 

 

 

 

 

 

 

Delay. These reports are sent immediately in all cases.

 

 

 

 

 

 

 

 

 

 

 

 

Swinger Bypass: The Swinger Count prompt in the System Configuration Group

 

 

 

X

X

 

 

 

X

 

X

 

sets the swinger count for this Swinger Bypass point option. When the number of

 

 

 

 

 

 

 

 

 

 

 

 

alarms or troubles in an armed or disarmed period reaches the swinger count, the

 

 

 

 

 

 

 

 

 

 

 

 

system automatically bypasses points programmed for Swinger Bypass. Turning the

 

 

 

 

 

 

 

 

 

 

 

 

system off clears the bypass. If a 24-hour point swinger bypasses while the system is

 

 

 

 

 

 

 

 

 

 

 

 

off, turning the system on (starting exit delay) and then turning the system off

 

 

 

 

 

 

 

 

 

 

 

 

(pressing [CLEAR]) clears the bypass. Swinger bypass is a point trouble and

 

 

 

 

 

 

 

 

 

 

 

 

activates the Point Trouble Relay function.

 

 

 

 

 

 

 

 

 

 

 

 

When a point is swinger bypassed, the Point Trouble Relay is activated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Output: Points programmed for alarm output provide output at Terminals 4

 

 

 

 

 

X

X

X

X

 

X

 

and 5 as part of the alarm response. Fire points provide a pulsed output. Non-Fire

 

 

 

 

 

 

 

 

 

 

 

 

points provide a steady output. Output lasts for the duration programmed in Bell

 

 

 

 

 

 

 

 

 

 

 

 

Time. Fire output always takes precedence over non-fire output.

 

 

 

 

 

 

 

 

 

 

 

 