10 Sys Res Group

2000 Series Program Entry Guide 4.0

Receiver

 

 

10 Sys Res Group

Default: 0

Selection: 0 to 9, B to F

1Successful connection to a remote programmer.

2Not used.

3Control panel reset with the stand-by switch (refer to the Installation Guide) or a remote programmer.

4Not used.

5 Not used.

6 Not used.

7 Reports missing or low battery restored.

8 Restored AC power.

9 Communication Restoral event for Phone 1.

B Communication Failure event for Phone 2.

C RF tamper restore (points or receiver).

D RF battery restore.

E RF receiver 7 restoral.

F RF receiver 8 restoral.

11 Duress Group

Default:

0

 

 

Selection:

0 to 9, B to F

 

 

1 to 3

Not used.

 

 

4

This report transmitted after six

 

attempts to enter an invalid passcode.

 

 

5

Duress passcode entered at keypad.

 

Refer to Code 8 = Duress in Section

 

15.0 Passcodes.

 

 

7, 8

Not used.

 

 

12 Test Group

Default:

0

Selection:

0 to 9, B to F

 

 

1 to 5

Not used.

 

 

6

Service stop.

 

 

7

Service start.

 

 

8

Test Report.

 

 

Bosch Security Systems 7/05 35114F