1.0 System Configuration

The System Configuration Group contains the Account Number, Swinger Count, Keyswitch, Custom Idle Text, and Custom Service Text prompts.

1 Account Number

Default: 0000

Selection: 0 to 9, B to F

Enter four characters for the Account Number to transmit to the receiver. Enter leading zeroes (0) for account numbers with fewer than four digits. For example: Enter 0123 for account number 123.

2 Swinger Count

Default: 4

Selection: 1, 2, 3, 4

The Swinger Count prompt sets the swinger count for the Swinger Bypass point option. When the number of alarms or troubles reaches the swinger count, the system automatically bypasses points programmed for Swinger Bypass. Turning the system off clears the bypass. If a 24-hour point swinger bypasses while the system is off, turning the system on (starting exit delay) and then turning it off (pressing [CLEAR] during exit delay) clears the bypass. Swinger bypass is a point trouble and activates the Point Trouble Relay function.

When a point is Swinger Bypassed, the Point Trouble Relay function activates. Refer to Section 13.2 Relay Functions.

SIA recommends the swinger count be set to 1.

Using Digit 2 of the point code assigns the Swinger Bypass feature to a point.

3 Keyswitch

Default:

Momentary

Selection:

Easikey, Momentary

 

 

0

Easikey

 

 

1

Momentary

 

 

Refer to the Installation Guide for instructions on connecting a momentary keyswitch to a point.

This control panel is not compatible with maintained contact keyswitches.

Operating the keyswitch (shorting the point) turns the system All On with delays if the system is off. Any faulted controlled points (Point Code Digit 1 = 6, 7, 8, 9, B, or C) are automatically bypassed.

If the system is All On or Part On, with or without delays, operating the keyswitch (shorting the point) turns the system off.

Leave the Keyswitch prompt set to Momentary if you are not using a keyswitch on your system.

Setting the Keyswitch prompt to Easikey allows a properly connected Easikey system to disarm the system. It cannot be used to arm the system. If the system is All On or Part On, with or without delays, presenting the electronic key to the Easikey reader (the Easikey shorts the point) turns the system off. If the system is off, presenting the electronic key to the Easikey reader (the Easikey shorts the point) has no effect.

4 Custom Idle Text1

5 Custom Idle Text2

Default: Bosch Security Systems

Selection: A to Z, 0 to 9, ! # , . - / : < >

The system displays at all text keypads the two lines of custom text you enter here whenever the system is off and idle. Each line contains a maximum of sixteen characters.

It can take up to 15 seconds for the custom text you program here to appear in all text keypads connected to the system.