Point Codes

 

 

EN 40

Table 5: continued

Display

Selection

Description

9

Controlled, Part, No

When control panel is All or Part On (armed), short or open causes alarm

 

Delay

response.

 

 

Part points must be normal (not faulted) or bypassed before control panel

 

 

can be Part armed.

 

 

If an alarm occurs on these points within 2 minutes of a closing (exit time

 

 

expired, Excursion/Exit included), the system sends a RECENT CLOSING

 

 

message with the Alarm Report.

 

 

If these points are faulted at the end of exit delay, the system waits a period

 

 

equal to entry delay before sending an Alarm Report. If the system is not

 

 

turned off, it sends an EXIT ERROR message with the Alarm Report.

 

 

Missing Controlled points generate an alarm response when on, a trouble

 

 

response when off.

 

 

RF Tamper for a Controlled point generates an alarm response when on, a

 

 

trouble response when off.

A

Keyswitch

Shorting then restoring Keyswitch points toggles the control panel from All

 

 

(or Part) On to off, off to All On.

 

 

The trouble option (refer to Section 11.3 Digit 3, Point Options)determines

 

 

how Keyswitch points respond to opens when the system is off. When the

 

 

system is All or Part On, an open produces an alarm response. A keyswitch

 

 

always causes a trouble condition if it is opened in the off state, regardless

 

 

of the value programmed in Digit 3.

 

 

If an alarm occurs on these points within 2 minutes of a closing (exit time

 

 

expired, Excursion/Exit included), the system sends a RECENT CLOSING

 

 

message with the Alarm Report.

 

 

Missing Keyswitch points generate an alarm response when on, a trouble

 

 

response when off.

 

 

RF Tamper for Keyswitch points generates an alarm response when on, a

 

 

trouble response when off.