3. INSTALLATION
Lock the cord clamp securely.
<Removal>
Press the tab.
<Securing>
3261B
Connectors | Connection location on | Cord clamps | ||
| main P. C. board | |||
|
|
| ||
X pulse motor encoder | P17 | (2) | ||
Y pulse motor encoder | P18 | (2) | ||
Work clamp pulse motor encoder | P19 | (2) | ||
Machine head switch | P14 | (2) | ||
Conversion harness | P15 | (PEDAL) | (2) | |
Machine head memory | P16 | (2) | ||
Thread trimmer solenoid | P2 | (SOL1) | (1) | |
Tension release solenoid | P3 | (SOL2) | (1) | |
X pulse motor | P21 | (XPM) | (1) | |
Y pulse motor | P22 | (YPM) | (1) | |
Work clamp pulse motor | P23 | (PPM) | (1) | |
Operation panel | P32 | (PROGRAMMER) | (2) | |
Home position sensor | P8 | (SENSOR1) | (2) (3) | |
STOP switch | P9 | (HEAD) | (2) (3) | |
Valve harness | P35 | (2) (3) |
NOTE: Route the X, Y and work clamp pulse motor harnesses so that they do not touch the power supply P.C. board.
11 |