6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
Sewing patterns that have been recorded in user programs can be recorded in up to 30 cycle programs (C01 to C30). One cycle program can contain up to a maximum of 50 steps (St1 to St50).
When sewing the sewing patterns in a certain order, it can be useful to record them in a cycle program beforehand.
*If memory switch No. 400 is set to OFF, cycle program setting and selection cannot be carried out.
<Recording method>1 | Switch to cycle program recording mode. | While pressing the TEST key, press the |
| key (1). |
| ||||||||
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| 2436B 2382B | |||
|
|
| ・ The cycle program number (C01 to C30) will be | ||||||||||
|
|
| displayed in the PROGRAM No. display, the step | ||||||||||
|
|
| number (St1 to St50) will be displayed in the menu | ||||||||||
|
|
| display, and the program number will be displayed in | ||||||||||
|
|
| the TENSION display. |
|
|
|
|
|
|
|
| ||
| 3102B | TEST indicator flashes | ・ If no program has been recorded for a step, | ||||||||||
| be displayed for that step. |
|
|
|
|
|
| ||||||
2 | Select a cycle program number. |
| Press the | or | key | to | select | the | cycle | program | |||
|
|
| number that you would like to use. |
|
|
|
|
|
| ||||
|
|
| • ‘St 1’ will be displayed. |
|
|
|
|
|
|
|
| ||
| 3103B | TEST indicator flashes |
|
|
|
|
|
|
|
|
|
|
|
3 | Select the program number to be recorded in step 1. | Press the | or | key | (2) to | display | the | program | |||||
|
|
| |||||||||||
|
|
| number to be recorded in the TENSION display (3). |
|
| ||||||||
|
|
| ・ If the value is changed, | the display | will change | to | |||||||
|
|
| flashing. |
|
|
|
|
|
|
|
|
|
|
|
|
| ・ To cancel the recording, keep the RESET key | ||||||||||
|
|
| pressed for more than 2 seconds so | that | is | ||||||||
|
|
| displayed. |
|
|
|
|
|
|
|
|
|
|
|
| TEST indicator flashes |
|
|
|
|
| 3104B | 2382B | 2383B | |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
4 | Apply the program setting. |
| Press the ENTER key. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| 2414B | |
|
|
| ・ The display will change from flashing to illuminated, | ||||||||||
|
|
| and this means that the setting has been applied. |
| |||||||||
|
|
| ・ If you press the | / | keys (4), the | / | keys (5) or | ||||||
|
|
| the TEST key without pressing the ENTER key, you | ||||||||||
|
|
| can cancel the parameter changes. |
|
|
|
|
|
43 |