6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)

6-3. Using cycle programs

Sewing patterns that have been recorded in user programs can be recorded in up to 30 cycle programs (C01 to C30). One cycle program can contain up to a maximum of 50 steps (St1 to St50).

When sewing the sewing patterns in a certain order, it can be useful to record them in a cycle program beforehand.

*If memory switch No. 400 is set to OFF, cycle program setting and selection cannot be carried out.

<Recording method>

1

Switch to cycle program recording mode.

While pressing the TEST key, press the

 

key (1).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2436B 2382B

 

 

 

The cycle program number (C01 to C30) will be

 

 

 

displayed in the PROGRAM No. display, the step

 

 

 

number (St1 to St50) will be displayed in the menu

 

 

 

display, and the program number will be displayed in

 

 

 

the TENSION display.

 

 

 

 

 

 

 

 

 

3102B

TEST indicator flashes

If no program has been recorded for a step, ‘---‘ will

 

be displayed for that step.

 

 

 

 

 

 

2

Select a cycle program number.

 

Press the

or

key

to

select

the

cycle

program

 

 

 

number that you would like to use.

 

 

 

 

 

 

 

 

 

‘St 1’ will be displayed.

 

 

 

 

 

 

 

 

 

3103B

TEST indicator flashes

 

 

 

 

 

 

 

 

 

 

 

3

Select the program number to be recorded in step 1.

Press the

or

key

(2) to

display

the

program

 

 

 

 

 

 

number to be recorded in the TENSION display (3).

 

 

 

 

 

If the value is changed,

the display

will change

to

 

 

 

flashing.

 

 

 

 

 

 

 

 

 

 

 

 

 

To cancel the recording, keep the RESET key

 

 

 

pressed for more than 2 seconds so

that

‘---‘

is

 

 

 

displayed.

 

 

 

 

 

 

 

 

 

 

 

 

TEST indicator flashes

 

 

 

 

 

3104B

2382B

2383B

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Apply the program setting.

 

Press the ENTER key.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2414B

 

 

 

The display will change from flashing to illuminated,

 

 

 

and this means that the setting has been applied.

 

 

 

 

If you press the

/

keys (4), the

/

keys (5) or

 

 

 

the TEST key without pressing the ENTER key, you

 

 

 

can cancel the parameter changes.

 

 

 

 

 

43