3. INSTALLATION

3-9. Connecting the power cord

CAUTION

Be sure to connect the ground. If the ground connection is not secure, you run a high risk of receiving a serious electric shock, and problems with correct operation may also occur.

< Seen from underneath table >

Control box

Connect cords that match the voltage specifications.

< EU specifications

(1)Filter box

(2)Screws [4 pcs]

(3)Staples [7 pcs]

(4)Power cord

1.Attach an appropriate plug to the power cord (4). (The green and yellow wire is the ground wire.)

2.Insert the power plug into a properly-grounded electrical outlet.

NOTE:

Take care when tapping in the staples

(3) to make sure that they do not pierce the cords.

Do not use extension cords, otherwise machine operation problems may result.

Leg

Green and yellow wire (ground wire)

2353B

BAS-311H

14