10. STANDARD ADJUSTMENTS

<Stepping clamp connecting rod position adjustment>

5014Q

Index mark

3138B

5015Q

1.Loosen the screw (1), and then open the cover (2).

2.Loosen the nut (3), and then adjust the position of the stepping clamp connecting rod (4).

When the stepping clamp connecting rod (4) is raised, the intermittent stroke will increase.

When the stepping clamp connecting rod (4) is lowered, the intermittent stroke will decrease.

Next, adjust the needle bar and presser foot timing.

3.Turn the pulley in the direction of the arrow to raise the needle bar from the lowest position until the lowest reference line on the needle bar (reference line B) is aligned with the lower edge of the needle bar bush (5).

(If using a DP x 5 needle, align with the second reference line from the top (reference line b).)

4.Open the top cover and loosen the two set screws (6).

5.Align the index marks of the stepping clamp cam (7) and the stepping clamp connecting rod (4), and then tighten the two set screws (6).

Check the following after changing the intermittent stroke.

3139B

3239B

 

 

 

 

 

 

 

 

 

 

 

 

 

Needle plate

1.With the intermittent presser foot (1) lowered, turn the pulley in the direction of the arrow to move the intermittent presser foot (1) to its lowest position.

2.Check that the presser foot (1) does not touch the needle plate and that the presser bar clamp (2) does not touch the presser bar bush (3).

<If they are touching> Remove the motor cover (4).

Loosen the nut (5), and turn the bolt (6) until it is pressing against the intermittent drive lever (7), and then adjust until the two points mentioned above are not touching.