11.LIST OF ERROR CODES
DataCode | Cause of error and remedy | |
E500 | The enlargement ratio setting caused the sewing data to extend outside the sewing area. | |
Set the enlargement ratio again. | ||
| Press the RESET key to clear the error. | |
E502 | The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm. | |
Press the RESET key to clear the error. Set the enlargement ratio again. | ||
| ||
E510 | Error in sewing data. | |
Press the RESET key to clear the error. | ||
| If an error occurs while reading or revising the sewing data, revise the data. | |
E511 | No end code has been input into pattern data. | |
Press the RESET key to clear the error. | ||
| ||
E512 | Number of stitches exceeds allowed maximum. | |
Press the RESET key to clear the error. | ||
| ||
| Memory switch file cannot be read correctly. | |
E581 | The model for the data which was read does not match the model being written to. | |
| Press the RESET key to clear the error. Read data for the same sewing machine model. | |
E582 | Memory switch versions do not match. | |
Press the RESET key to clear the error. Read data for the same version. | ||
| ||
E583 | User program versions do not match. | |
Press the RESET key to clear the error. Read data for the same version. | ||
| ||
Code | Cause of error and remedy | |
E600 | Upper thread breakage occurred. Thread the upper thread. | |
Turn off the power, and then check that connector P14 on the main P.C. board is properly connected. | ||
| ||
E670 | Problem with the lower thread detector. | |
Turn off the power, and then check the lower thread detector. | ||
|
75 |