10. STANDARD ADJUSTMENTS

10-15. Adjusting the work clamp lift amount<Motor-driven work clamp specifications>

The operation panel settings can be used to adjust the height to within 15 25 mm. (Refer to "5-5. Setting the work clamp lift amount.")

<Pneumatic work clamp specifications>

The maximum lift amount for the work clamp is 30 mm above the surface of the needle plate.

Max. 30mm

5018Q

3143B

1.Turn on the air, and then depress the work clamp switch (1) to raise the work clamp (2).

2.Loosen the two bolts (4) of the work clamp arm lever (3), and move the work clamp arm lever (3) up or down to adjust.

10-16. Adjusting the air pressure (pneumatic work clamp specifications)

Lift up the handle (2) of the regulator (1) and then turn it to adjust the air pressure to 0.5 MPa.

After adjustment is complete, push the handle (2) downward to lock it.

If water has collected in the bottle of the regulator (1), turn the drain cock (3) in the direction indicated by an arrow to drain the water.

NOTE:

Open the air cock (4) slowly.

1912B

BAS-311H

68