10. STANDARD ADJUSTMENTS

3353B

 

3354B

 

 

 

 

 

 

3356B

7.Loosen the two screws (9), and then remove the cover (10).

8.Loosen the bolt (11).

9.Move the movable knife connecting plate (13) back and forth to adjust so that the distance from the ridge on the right side of the needle plate to the ridge on the movable knife (12) is 9.5 to 9.9 mm.

10.After tightening the bolt (11), check the above position once more.

* Ignore the index mark on the needle plate.

11.Replace the cover (10).

12.Check that there is a gap of about 0 - 1 mm between the outside of the hole in the movable knife (12) and the ridge line on the shuttle race thread guide (14) when there is still play between the parts.

BAS-311H

62