No. | Setting | Setting items | Initial value | |
range | ||||
|
|
| ||
| Work clamp lift timing after sewing is completed |
| ||
001 | 0 | Work clamp is not raised automatically. | 2 | |
1 | Work clamp is raised at the final stitch position. | |||
|
| |||
| 2 | Work clamp is raised after moving to the home position. |
| |
| Work clamp | lowering sequence for separate work clamp (pneumatic work clamp specifications |
| |
002 | only) |
| 0 | |
0 | Left and right work clamps are lowered at the same time. | |||
| 1 | Work clamp is lowered in the order left |
| |
| 2 | Work clamp is lowered in the order right |
| |
| Work clamp | lowering operation |
| |
|
| Analog lowering: Work clamp is lowered in direct proportion to the pedal |
| |
| 0 | depression amount, and sewing starts when the pedal is fully depressed. |
| |
| *This operation is only possible for foot switch specifications; for |
| ||
|
|
| ||
003 |
| switch specifications, operation is the same as for a | 2 | |
1 | ||||
|
| |||
| step, and sewing starts when pedal is depressed to the 2nd step. |
| ||
|
|
| ||
|
|
| ||
| 2 | depressed to the 1st step, and work clamp is fully lowered and sewing starts when |
| |
|
| the pedal is depressed to the 2nd step. |
| |
| Slow start method |
| ||
|
| The sewing speed for the first 5 stitches will be in accordance with the setting for | OFF | |
100 | OFF | memory switch Nos. 151 to 155. (Ask the place of purchase for details on memory | ||
| ||||
| switch Nos. 151 to 155.) |
| ||
|
|
| ||
| ON | The sewing speed for the first 5 stitches can be selected from the nine slow start | Lo4 | |
| patterns “Lo1” to “Lo9”. (Refer to | |||
|
|
| ||
| test feed |
| ||
| OFF | Test feed starts when the foot switch (start switch) is depressed, and it continues |
| |
| automatically until the final stitch. |
| ||
200 |
| OFF | ||
| Test feed starts when the foot switch (start switch) is depressed, and it moves | |||
| ON | forward by one stitch each time the switch is depressed. In addition, when the |
| |
| TEST indicator is flashing, test feed will move forward one stitch at a time when |
| ||
|
|
| ||
|
| the machine pulley is turned by hand. |
| |
300 | Production counter display | OFF | ||
OFF | Lower thread counter display | |||
| ON | Production counter display |
| |
400 | Sewing condition detail settings | OFF | ||
OFF | Parameters which are common to all programs are used. | |||
| ON | Parameters can be set separately for each program. |
| |
402 | Unit display for pattern zoom ratio | OFF | ||
OFF | Displayed as %. | |||
| ON | Displayed as mm. |
| |
403 | Split mode selection | 0 | ||
0 | Continuous split mode | |||
| 1 | Single split mode |
| |
405 | Cycle program | No. (C01 to C30) display | ON | |
OFF | Disabled (not displayed) | |||
| ON | Enabled (displayed) |
|
41 |