6.USING THE OPERATION PANEL (ADVANCED OPERATIONS)6.USING THE OPERATION PANEL (ADVANCED OPERATIONS)6-1. Setting memory switches

1

Change the mode to memory switch setting mode.

While pressing the TEST key, press the TENSION key.

 

All indicators switch off

 

 

 

 

 

 

 

The memory switch number will appear in the

 

 

PROGRAM No. display, and the setting value for that

 

 

memory switch number will appear in the menu display.

 

Menu indicator switches off, TEST indicator flashes

 

 

 

3094B

2421B

 

 

 

 

 

 

2

Select the memory switch that you would like to change

Press the

or

key to

select the memory

switch

 

the setting for.

number.

 

 

 

 

 

 

 

 

 

 

3095B

 

If you would like to display only the numbers of

While pressing the SELECT key, press the or

key

 

memory switches that have been changed from default

(1).

 

 

 

 

 

settings

The numbers of memory switches that have been

 

 

changed from default settings will appear in order.

 

 

 

 

 

 

 

2423B

 

 

 

 

 

 

3

Change the memory switch parameters.

Press the

or

key to change the setting value.

 

 

 

The flashing display means that the setting has not yet been

 

 

applied.

 

 

 

 

 

 

You can make the initial setting appear in the display by

 

 

pressing the RESET key.

 

3096B

4

Apply the changed parameter setting.

Press the ENTER key.

 

 

 

 

The menu display will change from flashing to

 

 

illuminated, and this means that the setting has been

 

 

applied.

 

 

 

 

 

If you

press

the or

key (1) or the TEST key

 

2414B

without pressing the ENTER key, you can cancel the

 

parameter changes.

 

 

5

Repeat steps 2 to 4 above to set each memory switch.

 

 

 

 

 

 

 

 

 

 

6

Exit setting mode.

Press the TEST key.

 

 

 

 

The changes will be memorized and the sewing

 

 

machine will switch to home position detection standby.

 

TEST indicator switches off

 

 

 

 

2404B

BAS-311H

40