11. LIST OF ERROR CODES

Feed mechanism-related errors

Code

Cause of error and remedy

 

X-feed motor home position cannot be detected. Problem with X-feed motor or poor X home position sensor

E200

connection.

Turn off the power, and then check that connectors P17, P21 and P8 on the main P.C. board are properly

 

 

connected.

E201

X-feed motor stopped due to a problem.

Turn off the power, and then check if there are any problems in the X-feed direction.

 

Turn off the power, and then check that connectors P17 and P21 on the main P.C. board are properly connected.

E204

X-feed motor stopped due to a problem during sewing.

Turn off the power, and then check if there are any problems in the X-feed direction.

 

Turn off the power, and then check that connectors P17 and P21 on the main P.C. board are properly connected.

E205

X-feed motor stopped due to a problem while moving to the sewing start position.

Turn off the power, and then check if there are any problems in the X-feed direction.

 

Turn off the power, and then check that connectors P17 and P21 on the main P.C. board are properly connected.

 

X-feed motor stopped due to a problem during test feeding.

E206

Turn off the power, and then check if there are any problems in the X-feed direction.

 

Turn off the power, and then check that connectors P17 and P21 on the main P.C. board are properly connected.

 

Y-feed motor home position cannot be detected. Problem with Y-feed motor or poor Y home position sensor

E210

connection.

Turn off the power, and then check that connectors P18, P22 and P8 on the main P.C. board are properly

 

 

connected.

 

Y-feed motor stopped due to a problem.

E211

Turn off the power, and then check if there are any problems in the Y-feed direction.

 

Turn off the power, and then check that connectors P18 and P22 on the main P.C. board are properly connected.

 

Y-feed motor stopped due to a problem during sewing.

E214

Turn off the power, and then check if there are any problems in the Y-feed direction.

 

Turn off the power, and then check that connectors P18 and P22 on the main P.C. board are properly connected.

 

Y-feed motor stopped due to a problem while moving to the sewing start position.

E215

Turn off the power, and then check if there are any problems in the Y-feed direction.

 

Turn off the power, and then check that connectors P18 and P22 on the main P.C. board are properly connected.

E216

Y-feed motor stopped due to a problem during test feeding.

Turn off the power, and then check if there are any problems in the Y-feed direction.

 

Turn off the power, and then check that connectors P18 and P22 on the main P.C. board are properly connected.

E230

Feed motor stopped due to a problem.

Reduce the sewing speed or change the operation settings to the settings for heavy-weight materials.

 

Ask the place of purchase for details on the setting method.

BAS-311H

72