11. LIST OF ERROR CODES

11. LIST OF ERROR CODES

DANGER

Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the control box cover. Touching areas where high voltages are present can result in severe injury.

If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. Follow the remedy procedure to eliminate the cause of the problem.

Warnings displayed as symbols

Code

Cause of error and remedy

CLdn

The start switch was pressed without the work clamp being lowered.

First lower the work clamp.

 

 

UP

The needle bar is not stopped in the needle up stop position.

Turn the pulley until the point where the error display disappears.

 

 

Switch-related errors

Code

Cause of error and remedy

E010

The STOP switch was pressed.

Press the RESET key to clear the error.

 

 

The STOP switch was pressed.

E011

Press the RESET key to clear the error.

 

Press the ▼ key to move the feed mechanism so that you can continue sewing.

E012

The STOP switch was pressed.

Press the RESET key to clear the error, and then depress the start switch to move the feed mechanism to the

 

home position.

E015

The stop switch was still being pressed when the power was turned on, or there is a problem with the stop switch

connection.

 

Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.

E016

Problem with the stop switch connection.

Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.

 

E025

Start switch was being depressed when power was turned on.

(For a foot switch, the foot switch was being depressed to the 2nd step.)

 

Turn off the power and check the foot switch.

E035

Work clamp switch was being depressed when power was turned on.

(For a foot switch, the foot switch was being depressed to the 1st step.)

 

Turn off the power and check the foot switch.

 

Machine head tilting was detected after the power was turned on.

E050

Turn off the power, and then return the machine head to its original position.

 

Check that connector P14 on the main P.C. board is properly connected.

E051

Machine head tilting was detected while the sewing machine was operating.

Turn off the power, and then check that connector P14 on the main P.C. board is properly connected.

 

E055

Machine head tilting was detected when the power was turned on.

Turn off the power, and then return the machine head to its original position.

 

Check that connector P14 on the main P.C. board is properly connected.

E065

An operation panel key was still being pressed when the power was turned on, or key is faulty.

Turn off the power and check the operation panel.

 

BAS-311H