11. LIST OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the control box cover. Touching areas where high voltages are present can result in severe injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. Follow the remedy procedure to eliminate the cause of the problem.
Warnings displayed as symbolsCode | Cause of error and remedy | |
CLdn | The start switch was pressed without the work clamp being lowered. | |
First lower the work clamp. | ||
|
| |
UP | The needle bar is not stopped in the needle up stop position. | |
Turn the pulley until the point where the error display disappears. | ||
|
| |
Code | Cause of error and remedy | |
E010 | The STOP switch was pressed. | |
Press the RESET key to clear the error. | ||
| ||
| The STOP switch was pressed. | |
E011 | Press the RESET key to clear the error. | |
| Press the ▼ key to move the feed mechanism so that you can continue sewing. | |
E012 | The STOP switch was pressed. | |
Press the RESET key to clear the error, and then depress the start switch to move the feed mechanism to the | ||
| home position. | |
E015 | The stop switch was still being pressed when the power was turned on, or there is a problem with the stop switch | |
connection. | ||
| Turn off the power, and then check that connector P9 on the main P.C. board is properly connected. | |
E016 | Problem with the stop switch connection. | |
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected. | ||
| ||
E025 | Start switch was being depressed when power was turned on. | |
(For a foot switch, the foot switch was being depressed to the 2nd step.) | ||
| Turn off the power and check the foot switch. | |
E035 | Work clamp switch was being depressed when power was turned on. | |
(For a foot switch, the foot switch was being depressed to the 1st step.) | ||
| Turn off the power and check the foot switch. | |
| Machine head tilting was detected after the power was turned on. | |
E050 | Turn off the power, and then return the machine head to its original position. | |
| Check that connector P14 on the main P.C. board is properly connected. | |
E051 | Machine head tilting was detected while the sewing machine was operating. | |
Turn off the power, and then check that connector P14 on the main P.C. board is properly connected. | ||
| ||
E055 | Machine head tilting was detected when the power was turned on. | |
Turn off the power, and then return the machine head to its original position. | ||
| Check that connector P14 on the main P.C. board is properly connected. | |
E065 | An operation panel key was still being pressed when the power was turned on, or key is faulty. | |
Turn off the power and check the operation panel. | ||
|
70 |