5. USING THE OPERATION PANEL (BASIC OPERATIONS)

5-2. Program setting method

For details on the sewing data reading method, refer to “7. USING SD CARDS”.

1 Select the item to be changed.

Press the SELECT key.

 

The selected parameter changes in the order shown in

2401B

the illustration below each time the SELECT key is

pressed.

 

X-scale Æ Y-scale Æ Sewing speed Æ Slow start pattern Æ Counter Æ Split No. Æ Thread wiping

 

 

 

2

Change the setting for the parameter.

Press the or key to change the parameter setting.

 

(Refer to “5-2-1. Parameter list” on the next page

 

for details on parameter changes.

 

 

 

3072B

 

 

3

Repeat steps 1 to 2 above to record the settings for each parameter.

*When memory switch No. 400 is set to ON, the horizontal scale, vertical scale, sewing speed and work clamp height can be recorded separately for each program number.

*When memory switch No. 100 is set to ON, slow start patterns can be recorded separately for each program number.

*For details on memory switches, refer to “6-1. Setting memory switches”.

BAS-311H

30