3. INSTALLATION

3-8. Connecting the ground wire

CAUTION

Be sure to connect the ground. If the ground connection is not secure, you run a high risk of receiving a serious electric shock, and problems with correct operation may also occur.

3234B

(1)Ground wire from the machine head

(2)Ground wire from operation panel

(3)Ground wires from two-pedal foot switch harnesses (2 wires)

Tighten the control box cover with the six screws. Check that the cords are not clamped by the cover at this time.

NOTE: Make sure that the ground connections are secure in order to ensure safety.

13