11. LIST OF ERROR CODES

P.C. board-related errors

Code

Cause of error and remedy

E700

Abnormal rise in power supply voltage.

Turn off the power, and then check the input voltage.

 

E701

Abnormal rise in upper shaft motor drive voltage.

Turn off the power, and then check the voltage.

 

E705

Abnormal drop in power supply voltage.

Turn off the power, and then check the input voltage.

 

 

Abnormal current detected in upper shaft motor.

E710

Turn off the power, and then check if there are any problems with the sewing machine.

Turn off the power, and then check that connectors P11 and P1 on the motor P.C. board, connector P6 on the

 

 

main P.C. board and connector P4 on the upper shaft motor P.C. board are properly inserted.

E711

Abnormal current detected in pulse motor.

Turn off the power, and then check if there are any problems with the work clamp operation.

 

E730

External error input (AIRSW) detected.

Turn off the power, and then check the air pressure.

 

Version updating-related errors

Code

Cause of error and remedy

E870

No control program is present.

Install the control program.

 

E880

Version update requests cannot be received.

Turn off the power, and then turn it back on again.

 

E881

Version updating did not complete normally.

Turn off the power, and then repeat the version update procedure.

 

 

Communication error detected between the main P.C. board and the panel P.C. board.

E882

Turn off the power, and then check that connector P1 on the panel P.C. board, connector P5 on the main P.C.

 

board and connectors P2 and P3 on the motor P.C. board are properly inserted.

E883

No control program is present on the SD card.

Check that the control program has been saved into the correct folder.

 

E884

There is a problem with the control program.

Save the correct file onto the SD card.

 

E885

Version updating could not be carried out. Turn off the power, and then turn it back on again.

E887

 

If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem, contact the place of purchase.