REQUIREMENTS/SPECIFICATIONS

2.1.2STP Cable Specifications For The TRXI-42/44 Lobe Ports and TPIM-T1/T4

The TRXI-42 and TRXI-44 lobe ports support IBM Type 1, 2, 6, and 9 STP cabling as described below:

IBM Type 1 - Two STP lengths of 22 AWG solid wire for data. Used for the longest cable runs within the walls of buildings.

IBM Type 2 - Similar to Type 1 data cable, but having four additional UTP lengths of 22 AWG solid wire carried outside of the shield casing. Typically used for voice communication and often used to wire cable runs within the walls of buildings.

IBM Type 6 - Two STP lengths of 26 AWG stranded wire for data. This type is used in patch panels or to connect devices to/from wall jacks. Attenuation for Type 6 cable is 3/2 x Type 1 cable (66 m of Type 6 =100 meters of Type 1).

IBM Type 9 - Similar to Type 1, but uses 26 AWG solid wire. Attenuation for Type 9 cable is 3/2 x Type 1 cable

(66 m of Type 9 = 100 meters of Type 1).

Attenuation and Impedance

The attenuation values shown in Table 2-3 include the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the segment.

Table 2-3. STP Cable Specifications

Frequency

Impedance

Attenuation

 

 

 

 

 

 

Types 1 & 2

150Ω + 15%

 

4 MHz

<22 dB/km (6.7 db/1000 ft.)

16 MHz

150Ω + 15%

<45 dB/km (13.7 db/1000 ft.)

 

 

 

Types 6 & 9

150Ω + 15%

 

4 MHz

<33 dB/km (10 db/1000 ft.)

16 MHz

150Ω + 15%

<66 dB/km (20 db/1000 ft.)

 

 

 

Page 2-4

Page 15
Image 15
Cabletron Systems TRXI-44, TRXI-22, TRXI-42, TRXI-24 manual Requirements/Specifications