REQUIREMENTS/SPECIFICATIONS
2.1.4Multimode Fiber Optic Cable Specifications for the TPIM-F2
Table
Table
Cable Type | Attenuation | Maximum Drive Distance | |
|
|
| |
|
|
| |
50/125 ∝m | 13.0 dB or less | The maximum allowable fiber op- | |
|
| tic cable length is 2 km (2187.2 | |
62.5/125 ∝m | 16.0 dB or less | ||
yards). However, IEEE 802.5 | |||
|
| ||
100/140 ∝m | 19.0 dB or less | specifications allow for a maxi- | |
mum of 1 km (1093.6 yards). | |||
|
| ||
|
|
|
Maximum Trunk Lengths
The maximum trunk cable length between the TRXI and another active device is equal to the maximum drive distance as shown in Table
Attenuation
The fiber optic cable must be tested with a fiber optic attenuation test set that is adjusted for an 850 nm wavelength. This test verifies that the signal loss in a cable is within an acceptable level. Table
Fiber Optic Budget
When determining the maximum fiber optic cable length, the fiber optic budget delay should be calculated and taken into consideration before fiber optic cable runs are incorporated in any network design. Fiber optic budget is the combination of the optical loss due to the fiber optic cable,
Page