Cabletron Systems TRXI-24, TRXI-22, TRXI-42, TRXI-44 manual REQUIREMENTS/SPECIFICATIONS TPIM-F3

Models: TRXI-44 TRXI-42 TRXI-24 TRXI-22

1 92
Download 92 pages 46.74 Kb
Page 26
Image 26

REQUIREMENTS/SPECIFICATIONS

TPIM-F3

The TPIM-F3 shown in Figure 2-7 is an ST connector that supports Single Mode fiber Optic cabling.

RX

TX

LNK

 

 

 

 

TPIM-F3

Figure 2-7. The TPIM-F3

Note: Transmitter Power decreases as temperatures rise and increases as temperatures fall. Use the Output Power Coefficient to calculate increased or decreased power output for your operating environment. For example, the typical power output at 25°C is -16.4 dBm. For a 4°C temperature increase, multiply the typical coefficient

(-0.15 dBm) by four and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).

 

 

 

 

 

 

 

Maximum Sensitivity (-36.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive

 

 

 

 

 

 

Typical Sensitivity (-31.0)

 

 

 

 

Sensitivity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Sensitivity (-30.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Receive Input (-9.72)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Receive Input (-7.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Receive Input (-6.99)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmitter Power*

 

 

 

 

 

 

 

 

 

 

Maximum Transmit Power (-12.0)

 

(At 25°C into

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Transmit Power (-15.5)

 

8.3/125m fiber)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Transmit Power (-21.0)

 

dBm

-40

-35

-30

-25

-20

-15

-10

 

 

-5

0

 

Less Power

 

 

 

 

 

 

 

 

 

 

 

 

More Power

* Transmit Power

 

 

Typical Power

Minimum Power

 

Maximum Power

Coefficient

 

 

 

-0.15dBm/°C

 

-0.12 dBm/°C

 

 

-0.18 dBm/°C

 

 

 

 

 

 

 

Page 2-15

Page 26
Image 26
Cabletron Systems TRXI-24, TRXI-22, TRXI-42, TRXI-44 manual REQUIREMENTS/SPECIFICATIONS TPIM-F3