Cabletron Systems TRXI-42, TRXI-22, TRXI-24 REQUIREMENTS/SPECIFICATIONS TPIM-F2, Value Case Budget

Models: TRXI-44 TRXI-42 TRXI-24 TRXI-22

1 92
Download 92 pages 46.74 Kb
Page 25
Image 25

REQUIREMENTS/SPECIFICATIONS

TPIM-F2

The TPIM-F2 shown in Figure 2-6 is an ST connector that supports Multimode fiber Optic cabling.

RX

TX

LNK

 

 

 

 

TPIM-F2

Figure 2-6. The TPIM-F2

Note: The transmitter power levels and receive sensitivity levels given are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e. -30.5 dBm peak=-33.5 dBm average).

Parameter

Typical

Worst

Worst Case Typical

Receive

Value

Case

Budget

Budget

 

 

 

 

Sensitivity:

-30.5 dBm

-28.0 dBm

Peak Input

 

 

 

 

Power:

-7.6 dBm

-8.2 dBm

Transmitter Power

 

 

 

50/125 ∝m

 

 

 

 

fiber:

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125 ∝m

 

 

 

 

fiber:

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140 ∝m

 

 

 

 

fiber:

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate:

Better than 10-10

 

 