Cabletron Systems TRXI-22, TRXI-42 Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4

Models: TRXI-44 TRXI-42 TRXI-24 TRXI-22

1 92
Download 92 pages 46.74 Kb
Page 44
Image 44

INSTALLATION

3.8.4Connecting a Twisted Pair Segment to the TPIM-T2 or TPIM-T4

The TPIM-T2 supports UTP cabling and the TPIM-T4 supports STP cabling. The method for connecting an RJ45 connector to an RJ45 port is the same for both UTP and STP cabling. Before connecting a segment to the TPIM-T2 /T4, check each end of the segment to ensure the wires are pinned properly. To connect a segment to a TPIM-T2/T4:

1.Insert the RJ45 connector on the twisted pair segment into the RJ45 port on the TPIM as shown in Figure 3-14.

18

6

17

5

16

4

15

3

14

2

13

1

RO

LNK

TPIM-T2

LNK

TPIM-T2

RI

Figure 3-14. The TPIM-T2/T4

2.Check that the LNK LED on the TPIM lights green. If the LED lights red or is not lit, perform each of the following steps until it is:

a.Check that the device at the other end of the segment is on.

b.Verify that the RJ45 is pinned properly.

c.Check the cable for continuity.

d.Check that the twisted pair connection meets dB loss and cable specifications outlined in Chapter 2.

e.Check that the port is enabled through Local Management.

If a link still has not been established, contact Cabletron Systems Technical Support.