REQUIREMENTS/SPECIFICATIONS
Maximum Lobe Lengths
The lobe length is the physical length of the cable connecting a station to its TCU port at the TRXI. Table
Table
STP Cable Type | Ring Speed | ||
|
| 4 Mbps | 16 Mbps |
|
|
|
|
|
|
|
|
IBM Types 1 | & 2 | 200 meters | 100 meters |
|
| (660 feet) | (330 feet) |
|
|
|
|
IBM Types 6 | & 9 (only | 30 meters | 30 meters |
for station to wall jack | (99 feet) | (99 feet) | |
and patch panels) |
|
| |
|
|
|
|
Maximum Trunk Lengths
The maximum trunk cable length between the TRXI and another active device is equal to the maximum drive distance as shown in Table
Table
STP Cable Type | Ring Speed | |
| 4 Mbps | 16 Mbps |
|
|
|
|
|
|
IBM Types 1 & 2 | 770 meters | 346 meters |
| (2525 feet) | (1138 feet) |
|
|
|
IBM Types 6 & 9 | 513 meters | 230 meters |
| (1683 feet) | (755 feet) |
|
|
|
Maximum Number of Stations
When you use STP lobe cabling everywhere on the ring, the TRXI can support up to 250 stations at ring speeds of either 4 or 16 Mbps.