Table 1B — Physical Data — 48EJ,EK,EW,EY Units

UNIT 48EJ,EK,EW,EY

 

 

024D/E

 

 

 

 

028D/E

 

 

 

 

030D/E

 

 

 

 

034D/E

 

NOMINAL CAPACITY (tons)

 

20

 

 

 

 

25

 

 

 

 

 

27.5

 

 

 

 

 

30

 

 

 

OPERATING WEIGHT (lb)

 

 

 

 

 

 

 

 

 

For Operating Weights see Table 2.

 

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type Ckt 1

 

 

 

06D328

 

 

 

 

06D328

 

 

 

 

06D537

 

 

 

 

06D537

 

Ckt 2

 

 

 

06D818

 

 

 

 

06D328

 

 

 

 

06D328

 

 

 

 

06D537

 

Number of Refrigerant Circuits

 

2

 

 

 

 

2

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

Oil (oz) (Ckt 1, Ckt 2)

 

115, 88

 

 

 

 

 

 

115 ea.

 

 

 

 

115 ea.

 

 

 

 

115 ea.

 

REFRIGERANT TYPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R-22

 

 

 

 

 

 

 

 

 

 

 

 

Operating Charge (lb-oz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit 1*

 

 

25-0

 

 

 

 

25-0

 

 

 

 

 

25-0

 

 

 

 

 

25-0

 

 

 

Circuit 2

 

 

31-0

 

 

 

 

25-0

 

 

 

 

 

25-0

 

 

 

 

 

25-0

 

 

 

CONDENSER COIL

 

 

 

 

 

 

Cross-Hatched 3/8Copper Tubes, Aluminum Lanced, Aluminum Pre-Coated, or Copper Plate Fins

 

Quantity

 

 

1

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

Rows...Fins/in.

 

 

4...15

 

 

 

 

4...15

 

 

 

 

 

4...15

 

 

 

 

 

4...15

 

 

 

Total Face Area (sq ft)

 

33.3

 

 

 

 

33.3

 

 

 

 

 

33.3

 

 

 

 

 

33.3

 

 

 

CONDENSER FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

Propeller Type

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Cfm

 

 

13,420

 

 

 

 

13,420

 

 

 

 

 

13,420

 

 

 

 

 

13,420

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantity...Diameter (in.)

 

2...30

 

 

 

 

2...30

 

 

 

 

 

2...30

 

 

 

 

 

2...30

 

 

 

Motor Hp (1075 Rpm)

 

1

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

EVAPORATOR COIL

 

 

 

 

 

 

 

Cross-Hatched 3/8Copper Tubes,

Aluminum Plate Fins, Intertwined Circuits

 

 

 

 

 

 

Rows...Fins/in.

 

 

4...15

 

 

 

 

4...15

 

 

 

 

 

4...15

 

 

 

 

 

4...15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Face Area (sq ft)

 

31.7

 

 

 

 

31.7

 

 

 

 

 

31.7

 

 

 

 

 

31.7

 

 

 

EVAPORATOR FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

Centrifugal Type

 

 

 

 

 

 

 

 

 

 

 

 

Quantity...Size (in.)

 

 

 

2...20x15

 

 

 

 

2...20x15

 

 

 

 

2...20x15

 

 

 

 

2...20x15

 

Type Drive

 

 

 

Belt

 

 

 

 

Belt

 

 

 

 

Belt

 

 

 

 

Belt

 

Nominal Cfm

 

 

8,000

 

 

 

 

10,000

 

 

 

 

 

11,000

 

 

 

 

 

12,000

 

 

 

Motor Hp

 

5

 

10†

 

 

15

7.5

 

 

10†

 

 

15

 

10

 

15†

 

 

20

 

10

 

15†

 

 

20

Motor Frame Size (Standard)

S184T

 

S215T

 

 

D254T

S213T

 

 

S215T

 

 

D254T

 

S215T

 

D254T

 

 

S256T

 

S215T

 

D254T

 

 

S256T

(High Efficiency)

 

S184T

 

S215T

 

 

S254T

S213T

 

 

S215T

 

 

S254T

 

S215T

 

S254T

 

 

S256T

 

S215T

 

S254T

 

 

S256T

Motor Bearing Type

 

 

 

Ball

 

 

 

 

 

 

Ball

 

 

 

 

 

 

Ball

 

 

 

 

 

 

Ball

 

 

 

Maximum Allowable Rpm

 

1200

 

 

 

 

1200

 

 

 

 

 

1200

 

 

 

 

 

1200

 

 

 

Motor Pulley Pitch Diameter

4.9

 

4.4

 

 

5.7

5.4

 

 

6.1

 

 

5.5

 

4.4

 

4.9

 

 

5.9

 

4.4

 

5.7

 

 

5.9

Nominal Motor Shaft Diameter (in.)

11/8

 

13/8

 

 

15/8

13/8

 

 

13/8

 

 

15/8

 

13/8

 

15/8

 

 

15/8

 

13/8

 

15/8

 

 

15/8

Fan Pulley Pitch Diameter (in.)

12.4

 

8.6

 

 

9.1

12.4

 

 

11.1

 

 

8.7

 

9.4

 

8.1

 

 

8.7

 

9.0

 

9.1

 

 

8.7

Nominal Fan Shaft Diameter (in.)

 

 

115/16

 

 

 

 

 

 

115/16

 

 

 

 

 

 

115/16

 

 

 

 

 

 

115/16

 

 

 

Belt, Quantity...Type

 

1...BX56

 

2...BX50

 

2...5VX530

1...BX56

 

1...5VX570

 

 

2...5VX530

2...BX50

 

2...5VX500

 

2...5VX530

2...BX50

 

2...5VX530

 

2...5VX530

 

 

 

 

 

 

 

 

 

Belt, Length (in.)

 

56

 

50

 

 

53

56

 

 

59

 

 

57

 

50

 

50

 

 

53

 

50

 

53

 

 

53

Pulley Center Line Distance (in.)

16.0-18.7

 

15.6-18.4

 

15.0-17.9

15.6

 

-18.4

 

 

15.0-17.9

15.6-18.4

 

15.0-17.9

 

15.6-18.4

 

15.0-17.9

Factory Speed Setting (rpm)

717

 

924

 

 

1096

773

 

 

962

 

 

1106

 

848

 

1059

 

 

1187

 

884

 

1096

 

 

1187

FURNACE SECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rollout Switch Cutout Temp (F)**

 

225

 

 

 

 

225

 

 

 

 

 

225

 

 

 

 

 

225

 

 

 

Burner Orifice Diameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(in. ...drill size)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

Std

 

.111...34

 

 

 

 

.111...34

 

 

 

 

 

.111...34

 

 

 

 

 

.111...34

 

 

 

Liquid Propane

Alt

 

.089...43

 

 

 

 

.089...43

 

 

 

 

 

.089...43

 

 

 

 

 

.089...43

 

 

 

Thermostat Heat Anticipator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting (amps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stage 1

 

 

0.1

 

 

 

 

0.1

 

 

 

 

 

0.1

 

 

 

 

 

0.1

 

 

 

Stage 2

 

 

0.1

 

 

 

 

0.1

 

 

 

 

 

0.1

 

 

 

 

 

0.1

 

 

 

Gas Input (Btuh)

Stage 1 Low

 

265,600

 

 

 

 

265,600

 

 

 

 

 

265,600

 

 

 

 

 

265,600

 

 

 

 

High

 

398,400

 

 

 

 

398,400

 

 

 

 

 

398,400

 

 

 

 

 

398,400

 

 

 

 

Stage 2 Low

 

350,000

 

 

 

 

350,000

 

 

 

 

 

350,000

 

 

 

 

 

350,000

 

 

 

 

High

 

525,000

 

 

 

 

525,000

 

 

 

 

 

525,000

 

 

 

 

 

525,000

 

 

 

Efficiency (Steady State) (%)

 

82

 

 

 

 

82

 

 

 

 

 

82

 

 

 

 

 

82

 

 

 

Temperature Rise Range

 

15-45/35-65

 

 

15-45/35-65

 

 

 

15-45/35-65

 

 

 

15-45/35-65

 

Gas Pressure to Unit Range (in. wg)

 

5-13.5

 

 

 

 

5-13.5

 

 

 

 

 

5-13.5

 

 

 

 

 

5-13.5

 

 

 

Manifold Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

Std

 

3.5

 

 

 

 

3.5

 

 

 

 

 

3.5

 

 

 

 

 

3.5

 

 

 

Liquid Propane

Alt

 

3.5

 

 

 

 

3.5

 

 

 

 

 

3.5

 

 

 

 

 

3.5

 

 

 

Gas Valve Quantity

 

 

2

 

 

 

 

2

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

Field Gas Connection Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(in.-FPT)

 

 

1.5

 

 

 

 

1.5

 

 

 

 

 

1.5

 

 

 

 

 

1.5

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutout

 

 

426

 

 

 

 

426

 

 

 

 

 

426

 

 

 

 

 

426

 

 

 

Reset (Auto.)

 

 

320

 

 

 

 

320

 

 

 

 

 

320

 

 

 

 

 

320

 

 

 

LOW-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutout

 

 

7

 

 

 

 

7

 

 

 

 

 

7

 

 

 

 

 

7

 

 

 

Reset (Auto.)

 

 

22

 

 

 

 

22

 

 

 

 

 

22

 

 

 

 

 

22

 

 

 

RETURN-AIR FILTERS (W x H x T)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantity...Size (in.)

 

 

10...20 x 24 x 2

 

10...20 x 24 x 2

 

 

10...20 x 24 x 2

 

 

 

10...20 x 24 x 2

 

OUTDOOR-AIR FILTERS

 

 

8...16 x 25

 

 

 

 

8...16 x 25

 

 

 

 

8...16 x 25

 

 

 

 

8...16 x 25

 

Quantity...Size (in.)

 

 

 

4...20 x 25

 

 

 

 

4...20 x 25

 

 

 

 

4...20 x 25

 

 

 

 

4...20 x 25

 

POWER EXHAUST

 

 

 

 

 

 

Direct Drive, 3-Speed, Single-Phase Motor (Factory-Wired for High Speed) and Forward Curved Fan

 

Motor, Quantity...Hp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4...1

 

 

 

 

 

 

 

 

 

 

 

 

Fan, Diameter...Width (in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

11...10

 

 

 

 

 

 

 

 

 

 

 

 

*Sizes 024-034: Circuit 1 uses the lower portion of condenser coil, Circuit 2 uses the upper portion.

Sizes 038-048: Circuit 1 uses the left condenser coil, Circuit 2 the right. All units have intertwined evaporator coils. †Motor and drive shown will deliver approximately 2.5 in. wg net external static. For more information, see Table 3. **Rollout switch is manual reset.

NOTE: High heat is for 48EJ,EW only.

23

Page 23
Image 23
Carrier 48EW, 48EY024-068, 48AW, 48AY020-060, 48EK, 48AK, 48AJ Physical Data 48EJ,EK,EW,EY Units, Unit 48EJ,EK,EW,EY

48EJ, 48AJ, 48AK, 48EK, 48AY020-060 specifications

The Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY024-068 are cutting-edge rooftop air conditioning units designed for commercial applications. These models are renowned for their reliability, energy efficiency, and innovative technologies aimed at providing optimal indoor comfort.

One of the standout features of these units is their advanced cooling and heating capabilities. They employ a multi-stage compressor system that allows for precise temperature control, accommodating various load requirements. This flexibility is particularly beneficial in commercial settings where the cooling load can fluctuate throughout the day.

Energy efficiency is paramount in today’s environmental landscape, and Carrier has ensured that these models meet stringent efficiency standards. They incorporate high-efficiency scroll compressors, which significantly reduce energy consumption while delivering powerful performance. The units are also equipped with variable speed fans that adjust airflow based on demand, further optimizing energy use.

In terms of construction, these rooftop units feature a robust design that enhances durability and longevity. The cabinet is constructed to withstand harsh weather conditions, ensuring reliable performance year-round. Additionally, the units are equipped with corrosion-resistant coatings, particularly useful in coastal environments where salt exposure can be a concern.

The Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY models utilize advanced controls and connectivity features, allowing for easy integration into building management systems. This connectivity enables remote monitoring and control, facilitating quick response to changing conditions and simplifying maintenance tasks.

Noise reduction is another key characteristic of these models. They are designed with sound-absorbing insulation and low-noise fan blades to ensure quiet operation, making them suitable for noise-sensitive environments such as schools and hospitals.

These units are also available with various options for air filtration and dehumidification. The use of high-efficiency air filters enhances indoor air quality by trapping dust, pollen, and other airborne particles. Enhanced dehumidification capabilities ensure that spaces remain comfortable even in humid conditions.

In conclusion, the Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY024-068 rooftop units are engineered to offer exceptional performance, energy efficiency, and durability. With their advanced technologies and user-friendly features, they stand out as reliable solutions for meeting diverse commercial cooling and heating needs, making them a popular choice for many businesses.