Chapter 2 Setting Up The NAM Traffic Analyzer

Monitoring

Step 5 Accept the default settings or change the settings to the values you want to monitor. Click Submit to save your changes, or click Reset to cancel.

Voice

After you set up the NAM to monitor voice data, you will be able to view the collected voice data under the Analyze > Media menu in the NAM. For more information on viewing the voice data, see Media, page 3-37.

Note Voice monitoring features are supported with Cisco IP telephony devices only.

 

 

To set up voice monitoring:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 1

Choose Setup > Monitoring > Voice.

 

 

 

 

 

 

 

 

 

The Voice Monitoring page displays.

 

 

 

 

 

 

 

 

Step 2

Check the “Enable Call Signal Monitoring” check box.

 

 

 

 

 

 

 

Step 3

Accept the default MOS Score value range or modify the values as you prefer. See Table 2-37, Voice

 

 

Monitor Setup Window.

 

 

 

 

 

 

 

 

 

Table 2-37

Voice Monitor Setup Window

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voice Monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled

 

 

Enables voice monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOS Values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excellent

 

 

Highest quality MOS score (5.0 being highest). The default value is

 

 

 

 

 

5.00.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Good

 

 

Quality less than excellent; MOS score ranges from this setting to

 

 

 

 

 

less than excellent. The default value is 4.33.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fair

 

 

Quality less than good; MOS score ranges from this setting to less

 

 

 

 

 

than good. The default value is 4.02.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Poor

 

 

Quality less than excellent; MOS score ranges from this setting to

 

 

 

 

 

less than fair. The default value is 3.59.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2-38,Maximum and Default Voice/Video and RTP Stream Parameters per Platform provides the

 

 

maximum numbers allowed for various voice, video, and RTP streams depending on the NAM platform.

 

 

The default values for each parameter are in parenthesis.

 

 

 

 

 

 

 

 

Table 2-38

Maximum and Default Voice/Video and RTP Stream Parameters per Platform

 

 

 

 

 

 

 

 

 

 

 

Field

 

2220 Appliance

2204 Appliance

NAM-2(x)

NAM-1(x)

NME-NAM

 

 

 

 

 

 

 

 

 

 

 

 

 

RTP Streams

 

4,000 (2000)

 

1,500 (750)

800 (400)

400 (200)

100 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Active Calls

 

2,000 (1,000)

750 (375)

400 (200)

200 (100)

50 (25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Guide for the Cisco Network Analysis Module (NAM) Traffic Analyzer, 5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-22617-01

 

 

 

 

 

 

 

 

 

2-77

 

 

 

 

 

 

 

 

 

 

 

 