Chapter 2 Setting Up The NAM Traffic Analyzer

Alarms

Table 2-16

Conversation Alarm Thresholds (continued)

 

 

 

Field

 

Description

 

 

 

Severity

 

Choose High or Low. These will display on the Alarm Summary

 

 

dashboard (Monitor > Overview >Alarm Summary), where you

 

 

can choose to view High, Low, or High and Low alarms.

 

 

 

Source Site/Host

 

Make a selection from the drop-down lists, or leave as “Any.” See

 

 

Sites, page 2-58for information on setting up a site.

 

 

Destination Site/Host

Make a selection from the drop-down lists, or leave as “Any.” See

 

 

Sites, page 2-58for information on setting up a site.

 

 

 

Actions

 

From the lists, choose a Rising action and a Falling action

 

 

(optional). See Alarm Actions, page 2-36for information on setting

 

 

up alarm actions.

 

 

Conversation Metrics (per

Choose from one of the six metrics, and then enter a Rising

second)

 

threshold and a Falling threshold.

 

 

Add Metrics (button)

Click the Add Metrics button to add another row.

 

 

 

Delete (button)

 

Click the Delete button to remove that Metrics row.

 

 

 

Note If you leave a selection blank, it means that that parameter will not be considered. If you select “Any”, it will use any of the selections for that parameter, if encountered.

Step 4 Click Submit to set the thresholds, click Reset to reset the thresholds to their default value, or click Cancel to remove any changes you might have made.

Step 5 When finished, click Submit.

Setting Application Thresholds

Step 1 Choose Setup > Alarms > Thresholds.

Step 2 Click the Create button and choose the Application tab.

Step 3 The Application Alarm Threshold Configuration window displays. Fill in the fields as appropriate. Table 2-17, Application Alarm Thresholds describes the fields available on this screen.

Table 2-17

Application Alarm Thresholds

 

 

 

Field

 

Description

 

 

 

Name

 

Give the Application Alarm Threshold a name.

 

 

 

Site

 

Choose a site from the list. See Sites, page 2-58for information on

 

 

setting up a site.

 

 

 

Application

 

Choose an application from the list. You can start typing the first

 

 

few characters to narrow the list.

 

 

 

DSCP

 

Choose a DSCP value 0-63, or Any.

 

 

 

 

User Guide for the Cisco Network Analysis Module (NAM) Traffic Analyzer, 5.0

2-42

OL-22617-01

Page 76