3-33
User Guide for the Cisco Network Analysis Module (NAM) Traffic Analyzer, 5.0
OL-22617-01
Chapter 3 Monitoring and Analysis
Managed Device
Crossbar Switching Fabric
This option shows the Crossbar Switching Fabric information.
UpTime The time (in hundredths of a second) since the network
management portion of the system was last
re-initialized.
Location The physical location of this node.
Contact The textual identification of the contact person for this
managed node and information on how to contact this
person.
Modem Indicates whether the RS-232 port modem control lines
are enabled.
Baud rate The baud rate in bits per second of the RS-232 port.
Power Supply Description of the power supply being instrumented.
Power Supply Type The power supply source:
unknown
ac
dc
externalPowerSupply
internalRedundant
Power Supply Status The current state of the power supply being
instrumented.
1: normal
2: warning
3: critical
4: shutdown
5: notPresent
6: notFunctioning
Power Redundancy
Mode
Power Redundancy Mode:
The power-supply redundancy mode.
1: not supported
2: redundant
3: combined
Power Total Total current available for FRU usage.
When Redundancy Mode is redundant, the total current
available will be the capability of a power supply with
the lesser power capability of the two power supplies.
When Redundancy Mode is combined, the total current
available will be the sum of the capacities of all
operating power supplies.
Power Drawn Total Current Drawn by powered-on FRUs.
Table 3-16 Chassis Information (continued)
Field Description