Chapter 3 T1 and E1 Feature Cards

Configuring Input Impedance for the E1 Feature Card

Note For information about configuring the T1 or E1 ports, see the Cisco AS5350XM and Cisco AS5400XM Universal Gateways Software Configuration Guide.

Configuring Input Impedance for the E1 Feature Card

You can set the input impedance of the E1 feature card before or after running the setup script. For information on configuring the universal gateway with the setup script, see the Cisco AS5350XM and Cisco AS5400XM Universal Gateways Software Configuration Guide.

Configuration

 

To set the input impedance for the E1 feature card, use the line-terminationcommand.

 

 

 

 

Command

Purpose

Step 1

 

 

Router> enable

Enters enable mode.

 

Password: password

Enter the password. You have entered enable mode when

 

Router#

 

 

the prompt changes to Router#.

Step 2

 

 

Router# configure terminal

Enters global configuration mode. You have entered

 

Enter configuration commands, one per line. End

global configuration mode when the prompt changes to

 

with CNTL/Z.

Router(config)#.

 

Router(config)#

 

 

Step 3

 

 

Router(config)# controller e1 0

Enter the controller number on which you are configuring

 

Router(config-controller)#

input impedance.

Step 4

 

 

Router(config-controller)# line-termination

Sets the input impedance to 75 ohm for the controller.

 

75-ohm

The factory-set default is 120 ohm. Repeat Step 3 and

 

 

Step 4 for the other controllers.

Step 5

 

 

Router(config-controller)# Ctrl-Z

Returns to enable mode.

 

Router#

This message is normal and does not indicate an error.

 

%SYS-5-CONFIG_I: Configured from console by

 

console

 

 

 

 

Cisco AS5350XM and Cisco AS5400XM Universal Gateways Card Installation Guide

 

78-17406-01

3-11

 

 

 

Page 43
Image 43