Appendix A Technical Specifications

Cisco 810 Series

Table A-3

Cisco 819 ISR Specifications

 

 

 

 

 

 

 

 

 

Hardened Design

Non-Hardened Design

 

 

 

Specification

Specifications

 

 

 

 

 

Hardened Design Specifications

 

 

(Cisco 819HG and Cisco

(Cisco 819G and Cisco

 

Description

 

819HG-4G ISRs)

819G-4G ISRs)

(C819HGW and C819HWD ISRs)

 

 

 

 

Physical Characteristics

 

 

 

 

 

 

 

Dimensions (H x W x D)

1.73 x 7.7 x 8.1 in

1.67 x 7.7 x 7.2 in

1.73 x 7.7 x 9.0 in

 

 

(44 x 196 x 206 mm)

(42 x 196 x 183 mm)

(44 x 196 x 229 mm)

 

 

 

 

 

Weight

 

3.3 lb (1.5 kg)

2.3 lb (1.0 kg)

3.4 lb (1.54 kg)

 

 

 

 

Maximum Power

11 W

 

20 W

Consumption

 

 

 

 

 

 

 

 

Environmental Operating Ranges

 

 

 

 

 

 

Operating Temperature and

–13 to 140°F

32 to 104°F

–13 to 140°F

Altitude

 

(–25 to 60°C)

(0 to 40°C)

(–25 to 60°C)

 

 

 

 

 

 

 

 

 

Derate max operating temperature 1.5°C per 1000 feet above 5000 ft

 

 

 

 

 

 

 

10,000 ft maximum

 

 

 

 

 

 

 

Humidity

 

Maximum 95%

Maximum 85%

Maximum 95% non-condensing

 

 

non-condensing RH

non-condensing RH

RH

 

 

 

 

Environmental Tests

 

 

 

 

 

 

 

Ingress Protection Rating

IP 41 per IEC 60529 for

IP 20 per IEC 60529

IP 41 per IEC 60529 for Vertical

 

 

Vertical Falling Water,

 

Falling Water, Pollution Degree 3

 

 

Pollution Degree 3

 

 

 

 

 

 

 

Humidity

 

Non-condensing Relative Humidity: 5% to 95%

 

 

 

 

 

 

Pollution

 

Pollution 3 for Dust

 

 

 

 

Military Standard

MIL-STD-810G Method 514.6: Procedure 1 Category 4, Secured Cargo - Common Carrier

 

 

 

 

 

MIL-STD-810G Method 514.6: Procedure 1 Category 20, Ground Vehicles

 

 

 

 

 

MIL-STD-810G Method 516.6. Procedure 1, Functional Shock

 

 

 

 

 

MIL-STD-810G Method 516.6. Procedure 5, Crash Hazard

 

 

 

 

 

MIL-STD-810G Method 516.6. Procedure 6, Bench Handling

 

 

 

Vibration and Shock

EN61373 Functional Random Vibe - Category 1, Class B

 

(Railway Vehicles)

 

 

 

EN61373 Simulated Non-op Long-life Vibe - Category 1, Class B

 

 

 

 

 

 

 

 

EN61373 Non-op Shock, Class B

 

 

 

 

Heavy-Duty Vehicle

SAE J1455 Operating Random Vibe, Cab Mounted Truck

 

Applications

 

 

 

 

 

SAE J1455 Operating Sinusoidal Vibe, Category 3

 

 

 

 

 

 

 

 

 

 

SAE J1455 Non-operating Sinusoidal Vibe, Category 3

 

 

 

 

 

 

 

SAE J1455 Handling Drop Test

 

 

 

 

 

 

Certifications

 

 

 

 

 

 

 

 

 

Cisco Integrated Services Router Hardware Installation Guide

 

OL-27407-01

A-5

 

Page 231
Image 231
Cisco Systems OL-27407-01 manual Table A-3 Cisco 819 ISR Specifications