DGS-3024 Gigabit Ethernet Switch Manual

Figure 10- 13. Packet Size Analysis window (table)

The following fields can be set or viewed:

Parameter

Description

 

 

 

 

Time Interval

 

Select the desired setting between 1s and 60s, where "s" stands for seconds. The

 

 

 

default value is one second.

 

 

 

 

 

Record Number

 

Select the number of times the Switch will be polled between 20 and 200. The

 

 

 

default value is 20.

 

 

 

 

 

64

 

The total number of packets (including bad packets) received that were 64 octets in

 

 

 

length (excluding framing bits but including FCS octets).

 

 

 

 

 

65-127

 

The total number of packets (including bad packets) received that were between 65

 

 

 

and 127 octets in length inclusive (excluding framing bits but including FCS octets).

 

 

 

 

 

128-255

 

The total number of packets (including bad packets) received that were between

 

 

 

128 and 255 octets in length inclusive (excluding framing bits but including FCS

 

 

 

octets).

 

 

 

 

 

256-511

 

The total number of packets (including bad packets) received that were between

 

 

 

256 and 511 octets in length inclusive (excluding framing bits but including FCS

 

 

 

octets).

 

 

 

 

 

512-1023

 

The total number of packets (including bad packets) received that were between

 

 

 

512 and 1023 octets in length inclusive (excluding framing bits but including FCS

 

 

 

octets).

 

 

 

 

 

1024-1518

 

The total number of packets (including bad packets) received that were between

 

 

 

1024 and 1518 octets in length inclusive (excluding framing bits but including FCS

 

 

 

octets).

 

 

 

 

 

128

Page 142
Image 142
D-Link DSL-G604T manual 65-127, 128-255, 256-511, 512-1023, 1024-1518