Figure 10- 9. Rx Error Analysis window (table)

The following fields can be set:

Parameter

Description

 

 

 

 

Time Interval

 

Select the desired setting between 1s and 60s, where "s" stands for seconds. The

 

 

 

default value is one second.

 

 

 

 

 

Record Number

 

Select the number of times the Switch will be polled between 20 and 200. The default

 

 

 

value is 20.

 

 

 

 

 

CrcError

 

Counts otherwise valid packets that did not end on a byte (octet) boundary.

 

 

 

 

 

UnderSize

 

The number of packets detected that are less than the minimum permitted packets

 

 

 

size of 64 bytes and have a good CRC. Undersize packets usually indicate collision

 

 

 

fragments, a normal network occurrence.

 

 

 

 

 

OverSize

 

Counts packets received that were longer than 1518 octets, or if a VLAN frame is

 

 

 

1522 octets, and less than the MAX_PKT_LEN. Internally, MAX_PKT_LEN is equal to

 

 

 

1522.

 

 

 

 

 

Fragment

 

The number of packets less than 64 bytes with either bad framing or an invalid CRC.

 

 

 

These are normally the result of collisions.

 

 

 

 

 

Jabber

 

The number of packets with lengths more than the MAX_PKT_LEN bytes. Internally,

 

 

 

MAX_PKT_LEN is equal to 1522.

 

 

 

 

 

Drop

 

The number of packets that are dropped by this port since the last Switch reboot.

 

 

 

 

 

Show/Hide

 

Check whether or not to display Crc Error, Under Size, Over Size, Fragment, Jabber,

 

 

 

and Drop errors.

 

 

 

 

 