Based on the selected operation mode, the settings are applied.

Resetting Controller Configuration Using RACADM

To reset the controller configuration, use the following command:

racadm storage resetconfig:<Controller FQDD>

For more information, see the iDRAC RACADM Command Line Reference Guide available at dell.com/

esmmanuals.

12Gbps SAS HBA Adapter Operations

The non-RAID controllers are the HBAs that do not have few RAID capabilities. They do not support virtual disks.

iDRAC interface supports only 12 Gbps SAS HBA controller in this release.

You can perform the following for non-RAID controllers:

View controller, physical disks, and enclosure properties as applicable for the non-RAID controller. Also, view EMM, fan , power supply unit, and temperature probe properties associated with the enclosure. The properties are displayed based on the type of controller.

View software and hardware inventory information.

Update firmware for enclosures behind the 12 GBps SAS HBA controller (staged)

Monitor the polling or polling frequency for physical disk SMART trip status when there is change detected

Monitor the physical disks hot plug or hot removal status

Blink or unblink LEDs

NOTE:

You must perform Collect System Inventory On Reboot (CSIOR) operation before inventorying or monitoring the non-RAID controllers.

Reboot the system after performing a firmware update.

Real-time monitoring for SMART enabled drives and SES enclosure sensors is only done for the 12 GBps SAS HBA controllers.

Related Links

Inventory and Monitoring Storage Devices

Viewing System Inventory

Updating Device Firmware

Monitoring Predictive Failure Analysis On Drives

Blinking or Unblinking Component LEDs

Monitoring Predictive Failure Analysis On Drives

Storage management supports Self Monitoring Analysis and Reporting Technology (SMART) on physical disks that are SMART-enabled.