– Custom — Enter the percentage value.

The allowable range for minimum fan speed PWM is dynamic based on the system configuration. The first value is the idle speed and the second value is the configuration max (which may or may not be 100% based on system configuration).

System fans can run higher than this speed as per thermal requirements of the system but not lower than the defined minimum speed. For example, setting Minimum Fan Speed at 35% limits the fan speed to never go lower than 35% PWM.

NOTE: 0% PWM does not indicate fan is off. It is the lowest fan speed that the fan can achieve.

The settings are persistent, which means that once they are set and applied, they do not automatically change to the default setting during system reboot, power cycling, iDRAC, or BIOS updates. A few Dell servers may or may not support some or all of these custom user cooling options. If the options are not supported, they are not displayed or you cannot provide a custom value.

3.Click Apply to apply the settings. The following message is displayed:

It is recommended to reboot the system when a thermal profile change has been made. This is to ensure all power and thermal settings are activated.

Click Reboot Later or Reboot Now.

NOTE: You must reboot the system for the settings to take effect.

Modifying Thermal Settings Using RACADM

To modify the thermal settings, use the objects in the system.thermalsettings group with the set sub command as provided in the following table.

Object

Description

Usage

Example

 

 

 

 

AirExhaustT

Allows to set the maximum

Set to any of the

To check the existing setting on the

emp

air exhaust temperature limit.

following values

system:

 

 

(based on the

racadm get

 

 

system):

 

 

 

system.thermalsettings.AirE

0 - Indicates xhaustTemp 40°C

1 - Indicates

The output is:

AirExhaustTemp=70

 

45°C

2 - Indicates

This means that the system is set to

 

50°C

3 - Indicates

limit the air exhaust temperature to

70°C.

 

55°C

 

 

4 - Indicates

To set the exhaust temperature

 

60°C

limit to 60°C:

255 - Indicates

racadm set

 

70°C (default)

 

 

system.thermalsettings.AirE

 

 

xhaustTemp 4

56

Page 56
Image 56
Dell iDRAC8 manual Modifying Thermal Settings Using Racadm