The vFlash SD card is locked when an operation is in-progress. For example, during an initialize operation.
SNMP Authentication
Why is the message 'Remote Access: SNMP Authentication Failure' displayed?
As part of discovery, IT Assistant attempts to verify the get and set community names of the device. In IT
Assistant, you have the get community name = public and the set community name = private. By default,
the SNMP agent community name for iDRAC agent is public. When IT Assistant sends out a set request,
the iDRAC agent generates the SNMP authentication error because it accepts requests only from
community = public.
To prevent SNMP authentication errors from being generated, you must enter community names that are
accepted by the agent. Since the iDRAC only allows one community name, you must use the same get
and set community name for IT Assistant discovery setup.
Storage Devices
Information for all the storage devices connected to the system are not displayed and OpenManage
Storage Management displays more storage devices that iDRAC. Why?
iDRAC displays information for only the Comprehensive Embedded Management (CEM) supported
devices.
iDRAC Service Module
Before installing or running the iDRAC Service Module, should the Open Manage Server Administrator
be uninstalled?
No you do not have to uninstall Server Administrator. Before you install or run the iDRAC Service Module,
make sure that you have stopped the features of Server Administrator that the iDRAC Service Module
provides.
How to check whether iDRAC Service Module is installed in the system?
To know if the iDRAC Service Module is installed on the system,
On Windows:
Run the service.msc command. In the list of services displayed, see if there is a service called DSM
iDRAC Service Module.
On Linux:
Run the command /etc/init.d/dcismeng status. If the iDRAC Service Module is installed and
running, the status displayed is running.
NOTE: Use the systemctl status dcismeng.service command instead of the init.d
command to check if the iDRAC Service Module is installed on RedHat Enterprise Linux 7 operating
system.
How to check the version number of the iDRAC Service Module installed in the system?
To check the version of the iDRAC Service Module in the system, do any of the following:
335