SSH — Access iDRAC through firmware RACADM.
Telnet — Access iDRAC through firmware RACADM
Remote RACADM — Remotely access iDRAC.
SNMP Agent — Enables support for SNMP queries (GET, GETNEXT, and GETBULK operations) in
iDRAC.
Automated System Recovery Agent — Enable Last System Crash Screen.
VNC Server — Enable VNC server with or without SSL encryption.
Configuring Services Using Web Interface
To configure the services using iDRAC Web interface:
1. In the iDRAC Web interface, go to OverviewiDRAC SettingsNetworkServices.
The Services page is displayed.
2. Specify the required information and click Apply.
For information about the various settings, see the iDRAC Online Help.
Configuring Services Using RACADM
To enable and configure the various services using RACADM:
Use the following objects with the config command:
– cfgRacTuneLocalConfigDisable
– cfgRacTuneCtrlEConfigDisable
– cfgSerialSshEnable
– cfgRacTuneSshPort
– cfgSsnMgtSshIdleTimeout
– cfgSerialTelnetEnable
– cfgRacTuneTelnetPort
– cfgSsnMgtTelnetIdleTimeout
– cfgRacTuneWebserverEnable
– cfgSsnMgtWebserverTimeout
– cfgRacTuneHttpPort
– cfgRacTuneHttpsPort
– cfgRacTuneRemoteRacadmEnable
– cfgSsnMgtRacadmTimeout
– cfgOobSnmpAgentEnable
– cfgOobSnmpAgentCommunity
Use the objects in the following object groups with the set command:
– iDRAC.LocalSecurity
– iDRAC.LocalSecurity
– iDRAC.SSH
– iDRAC.Webserver
– iDRAC.Telnet
86